Solid cerebral microemboli and cerebrovascular symptoms in patients with prosthetic heart valves.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Although cerebral microemboli are often detected by transcranial Doppler ultrasonography in mechanical heart valve patients, the clinical significance of such microemboli is unclear. The aim of this study was to determine the frequency and composition of cerebral microemboli in a prosthetic heart valve population and to correlate these findings to cerebrovascular symptoms, blood inflammation, and coagulation parameters. METHODS Seventy-six consecutive patients with a total of 81 prosthetic (54 mechanical, 27 biologic) heart valves were monitored for cerebral microemboli by multifrequency transcranial Doppler ultrasonography 1 year after valve replacement. Cerebrovascular events in the first year were recorded by a neurologist. Inflammation and coagulation markers were measured by immunoassays. RESULTS Microemboli were detected in mechanical heart valve patients only (28 patients, 56%). Twelve percent were solid, occurring in 17 (34%) of the mechanical heart valve population. The presence of solid cerebral microemboli was the only variable that was associated with cerebrovascular symptoms after a final regression analysis (P=0.026). The plasma monocyte chemotactic protein-1 level was raised in patients with solid microemboli (P=0.014). CONCLUSIONS Solid cerebral microemboli were detected by multifrequency transcranial Doppler ultrasonography in 35% of a mechanical heart valve population, and the frequency was higher in patients who experienced cerebrovascular events during the first year after valve replacement. The results suggest that the detection of solid cerebral microemboli may be helpful in predicting the risk of ischemic stroke in mechanical heart valve patients.
منابع مشابه
Incidence of transcranial Doppler-detected cerebral microemboli in patients referred for echocardiography.
BACKGROUND AND PURPOSE Transcranial Doppler can detect cerebral microemboli. These emboli may be a risk factor for embolic stroke. We studied the prevalence of microemboli in patients referred for echocardiography. METHODS Forty-two patients were evaluated. Patients were studied with continuous monitoring over one middle cerebral artery for 30 minutes, and the number of microemboli was record...
متن کاملMicroemboli Monitoring in Ischemic Stroke
The detection is made possible because of the acoustic impedance between microemboli and blood, which increases the ultrasound intensity. Microemboli are transient (<100ms), high intensity (> 3dB) and unidirectional signal which are accompanied by a characteristic click or chirp sound (Ringelstein, Droste et al. 1998). The origin of microemboli are usually from an atheromatous plaque in the car...
متن کاملMicroemboli in cerebral circulation and alteration of cognitive abilities in patients with mechanical prosthetic heart valves.
BACKGROUND AND PURPOSE It has been shown previously that cerebral microemboli may occur frequently in patients with a normal mechanical heart valve (MHV) without prior history of stroke. Some arguments strongly suggest that these microemboli have a gaseous origin. In other circumstances such as extracorporeal circulation or decompression in divers, it has been demonstrated that cerebral microbu...
متن کاملOnline automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.
BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...
متن کاملPrevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves.
BACKGROUND AND PURPOSE Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in thr...