Agreement in human interpretation of analog thallium myocardial perfusion images.

نویسندگان

  • J E Atwood
  • D Jensen
  • V Froelicher
  • K Witztum
  • K Gerber
  • E Gilpin
  • W Ashburn
چکیده

To assess the agreement of human interpretation of analog thallium myocardial perfusion images, four experienced interpreters evaluated 100 images on two occasions using a form designed to limit reader variability. A high intraobserver agreement (agreement by same observer at separate times) of 89--93% was found when films were interpreted as normal or abnormal (a dichotomous decision). Interobserver agreement for a majority grouping of observers (three or four) was 75% for an abnormal and 68% for a normal interpretation. However, agreement ranged from 11--79% when interpreters were asked to read the anatomic location of defects. Posterior and lateral wall defects were interpreted with the least amount of agreement. These results indicate that caution must be taken when interpreting defect location. Using a scale of 1--10 to grade the severity of a defect, correlations of 0.82--0.86 were found when reading defects in the lateral and anterior projections. Higher correlations, from 0.86--0.94, were found in left anterior oblique views. Use of reporting forms with specific criteria, multiple observers at one occasion, and/or computer processing may improve agreement. A brief review of the agreement of cardiology testing procedures is also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

Tc-99m-MIBI in evaluation of myocardial perfusion [Persian]

Tc-99m-MIBI is an isonrtrile derivative used for evaluation of myocardial perfusion in recent years. In this preliminary report, 7 patients with coronary artery disease are evaluated with Tc-99m-MlBl stress planar and sped studies. Good correlation with coronary angiography is observed in these cases. In view of inherent technical problems present with thallium 201, Tc-99m-MIBi is a good ...

متن کامل

The first performance of myocardial perfusion scintigraphy, post intravenous Dipyridamole injection

SUMMARY Dipyridamolc-Thallium imaging is a relatively safe and accurate method to evaluate myocardial perfusion in patients who arc unable to exercise to a maximal exertion (5,6,8,9). A 51year-old woman was admitted to Taleghani hospital with clinical symptoms and signs of coronary artery disease. Intravenous dipyridamote-Thallium scan was performed in this case. In multiple views obtained f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 64 3  شماره 

صفحات  -

تاریخ انتشار 1981