Elliptic st. jude bileaflet mechanical heart valves

نویسندگان

  • Hadi Mohammadi
  • Mehdi Jahandardoost
  • Guy Fradet
چکیده

St. Jude Medical (SJM) bileaflet mechanical valves were approved by the Food and Drug Administration in 1977. The SJM valve design consists of two semicircular leaflets which pivot on hinges. Compared to other mechanical heart valve prostheses such as ball and cage and tilting disk prosthetic valves, it provides good central flow, the leaflets open completely, and the pressure drop across the valve is trivial. However, non-physiological hemodynamics around these valves may lead to red blood cells lysis and therombigenic complications. Also, the regurgitation-flow inSJM valves is almost twice that of the native valves in the aortic position. In this study, we suggest a new design for the stent (housing) of SJM valves in which 15% ovality is applied to the stent whereas its perimeter remains constant. In a pilot study, the hemodynamic performance of the proposed design is analyzed in the closing phaseand compared to that of conventional SJM models. Results show that while the elliptic SJM model offers a shorter closing phase (9.7% shorter), the regurgitation flow remains almost unchanged. In other words, even though the dynamic response of the valve is improved, the regurgitation flow is not decreased. Thus, a more efficient effective orifice area (EOA) is shown to be provided by the proposed model. The preliminary calculations presented in this study justify an improved hemodynamics of elliptic SJM valves compared to conventional models; the proposed design shows promise and merits further development.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-induced platelet activation in a St. Jude mechanical heart valve, a trileaflet polymeric heart valve, and a St. Jude tissue valve.

Polymer heart valves have been under investigation since the 1960s, but their success has been hampered by an overall lack of durability mainly due to calcification of the leaflets and a relatively high rate of thromboembolic complications. A new polymer (Quatromer) trileaflet design was tested for its thrombogenic potential and was compared to that of existing prosthetic heart valves routinely...

متن کامل

An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.

BACKGROUND AND AIM OF THE STUDY An integrated macro/micro approach was used to evaluate flow within the pivots of the Medtronic ADVANTAGE bileaflet heart valve. Results were compared with those obtained with the St. Jude Medical bileaflet heart valve. METHODS The integrated macro/micro approach consists of both a macroscopic hydrodynamic performance assessment and a three-part microscopic flo...

متن کامل

Mechanical heart valves: 50 years of evolution.

The past 50 years have witnessed remarkable progress in the development of safe, hemodynamically favorable mechanical heart valves. Starr-Edwards aortic and mitral ball valves introduced in the mid-1960s, continue to be used successfully worldwide. More than 100,000 Omniscience and Omnicarbon tilting-disc valves have been implanted since 1978 with essentially no mechanical failure; similar resu...

متن کامل

Regurgitant flow field characteristics of the St. Jude bileaflet mechanical heart valve under physiologic pulsatile flow using particle image velocimetry.

The regurgitant flow fields of clinically used mechanical heart valves have been traditionally studied in vitro using flow visualization, ultrasound techniques, and laser Doppler velocimetry under steady and pulsatile flow. Detailed investigation of the forward and regurgitant flow fields of these valves can elucidate a valve's propensity for blood element damage, thrombus formation, or cavitat...

متن کامل

Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves.

1. Permanent therapy with oral anticoagulants offers the most consistent protection in patients with mechanical heart valves. 2. Antiplatelet agents alone do not consistently protect patients with mechanical prosthetic heart valves, including patients in sinus rhythm with St. Jude Medical valves in the aortic position. 3. Levels of oral anticoagulants that prolong the INR to 2.0 to 3.0 appear s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015