Is Taurolidine-citrate an effective and cost-effective hemodialysis catheter lock solution? A systematic review and cost- effectiveness analysis

نویسندگان

  • Zahra Kavosi
  • Maryam Sarikhani Khorrami
  • Khosro Keshavarz
  • Abdosaleh Jafari
  • Amir Hashemi Meshkini
  • Hamid Reza Safaei
  • Shekoufeh Nikfar
چکیده

BACKGROUND Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other common alternatives in Iran. METHODS To evaluate the efficacy of taurolidine-citrate, a systematic review was conducted by searching electronic databases. The outcomes of interest for cost-effectiveness analysis were as follows: "Catheter-related bacteremia episodes"; "catheter-related bacteremia-free survival"; "catheter thrombosis rate" for efficacy evaluation and "reduction of catheter-related infection". For evidence synthesis, a meta-analysis was conducted on the extracted efficacy data. To evaluate the cost of treatments, direct medical costs were included, and the incremental cost-effectiveness ratio was calculated for each comparison. The payers' (patients and insurance companies) perspectives were used for cost analysis. RESULTS After carrying out the systematic process, three articles were included in the analysis. Considering 95% confidence interval, the relative difference was -0.16 (-0.25 to -0.07) for catheterrelated bacteremia episode, indicating that the rate of catheter-related infections in hemodialysis patients who used taurolidine-citrate was 16% less than in those hemodialysis patients who received heparin. Considering 95% confidence interval, the relative difference was 0.13 (-0.06 0.32) for catheter thrombosis, showing that the rate of catheter-related thrombosis in hemodialysis patients who used taurolidine-citrate was 13% more than in hemodialysis patients who received heparin. The results of this analysis indicated that taurolidine-citrate, compared to heparin, was more effective in preventing catheter-related infection; therefore, it could be considered as a superior strategy. Nevertheless, compared to heparin-gentamicin combination, taurolidine-citrate is an inferior strategy because of its higher cost and lower infection prevention. CONCLUSION Compared to heparin, taurolidine-citrate is a superior option, but it is an inferior strategy compared to heparin-gentamicin combination. The clinical evidences on taurolidine-citrate, heparin and gentamicin/heparin are not sufficient for making confident decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Taurolidine-citrate an effective and cost-effective hemodialysis cathe-ter lock solution? A systematic review and cost- effectiveness analysis

Background: Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other ...

متن کامل

Preventing catheter-related bacteremia with taurolidine-citrate catheter locks: a systematic review and meta-analysis.

BACKGROUND Preliminary evidence from some studies suggests that taurolidine-citrate locks decrease catheter-related bacteremia (CRB), which is a major cause of morbidity and mortality in patients using intravascular catheters. No previous study has sought to summarize existing evidence on the use of taurolidine-citrate locks. A systematic review and meta-analysis were undertaken to determine wh...

متن کامل

Antimicrobial lock solutions in the prevention of catheter-related bloodstream infections in patients receiving hemodialysis.

To the Editor—There is increasing evidence that antimicrobial locks applied within the catheter lumen are effective at preventing catheter-related bloodstream infection (CRBSI), a source of substantial morbidity and mortality in patients receiving hemodialysis (HD). Therefore, we read with interest the recently published review article by John Boyce that, in addition to providing a comprehensiv...

متن کامل

Taurolidine-citrate-heparin catheter lock solution reduces staphylococcal bacteraemia rates in haemodialysis patients.

BACKGROUND Infection is second only to cardiovascular disease as a cause of death in the haemodialysis (HD) population. AIM : To assess the effect of introducing catheter lock solution taurolidine-citrate-heparin to all tunnelled central venous catheters (TCVCs) on staphylococcal bloodstream infection rates in patients on chronic HD. DESIGN Observational, prospective analysis of the inciden...

متن کامل

Comparative Efficacies of Antimicrobial Catheter Lock Solutions for Fungal Biofilm Eradication in an in Vitro Model of Catheter-Related Fungemia

Fungal catheter-related bloodstream infections (CRBSIs)-primarily due to Candida species-account for over 12% of all CRBSIs, and have been progressively increasing in prevalence. They present significant health and economic burdens, and high mortality rates. Antimicrobial catheter lock solutions are an important prophylactic option for preventing fungal CRBSIs. In this study, we compared the ef...