Fusion after interspinous device placement.

نویسندگان

  • Nai-Feng Tian
  • Xiao-Lei Zhang
  • Yao-Sen Wu
  • Li-Bo Jiang
  • Hua-Zi Xu
  • Yong-Long Chi
چکیده

Lumbar interspinous devices are intended to unload the facet joints, restore foraminal height, lower intradisk pressure, and provide motion-preserving stabilization. They are an alternative treatment for patients with spinal degeneration and have increased in popularity in recent years. To the authors' knowledge, heterotopic ossification has not been previously reported around an interspinous device, and this is the first reported case of interspinous fusion after interspinous device placement.A 66-year-old man presented with a 3-year history of low back pain and a 4-month history of radiating pain down his left leg. A diagnosis was made of lumbar spinal stenosis and left disk herniation at L4-L5 after physical and imaging examinations. A dynamic interspinous device was implanted after the decompressive surgery. The patient's symptoms were relieved postoperatively. Thirty-two months later, he returned with back pain after being in a traffic accident. Lumbar radiographs showed a massive bony formation around the implant. Radiographs and a computed tomography scan 4.5 years later revealed that the implanted device segments were fused. No implant motion was seen on dynamic radiographs. Because the patient was symptom free, no interventions were performed.Heterotopic bone formation around a dynamic interspinous device may hamper motion preservation, and heterotopic ossification is a potential mid- and long-term complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grade 1 spondylolisthesis and interspinous device placement: removal in six patients and analysis of current data

BACKGROUND In the treatment of patients with Grade 1 spondylolisthesis, the use of interspinous devices has been controversial for nearly a decade. Several authors have suggested that Grade 1 spondylolisthesis be considered a contraindication for interspinous device placement. METHODS We removed interspinous devices in six symptomatic Grade 1 spondylolisthesis patients and analyzed pertinent ...

متن کامل

Efficacy of interspinous device versus surgical decompression in the treatment of lumbar spinal stenosis: a modified network analysis

STUDY DESIGN Systematic review using a modified network analysis. OBJECTIVES To compare the effectiveness and morbidity of interspinous-device placement versus surgical decompression for the treatment of lumbar spinal stenosis. SUMMARY Traditionally, the most effective treatment for degenerative lumbar spinal stenosis is through surgical decompression. Recently, interspinous devices have be...

متن کامل

Magnetic resonance imaging on disc degeneration changes after implantation of an interspinous spacer and fusion of the adjacent segment.

The aim of the study was to investigate the changes of the lumbar intervertebral disc degeneration by magnetic resonance imaging (MRI) after the implantation of interspinous device and the fusion of the adjacent segment. A total of 62 consecutive patients suffering L5/S1 lumbar disc herniation (LDH) with concomitant disc space narrowing or low-grade instability up to 5 mm translational slip in ...

متن کامل

A Novel Nonpedicular Screw-Based Fixation in Lumbar Spondylolisthesis

Objective. The authors present the clinical results obtained in patients who underwent interspinous fusion device (IFD) implantation following posterior lumbar interbody fusion (PLIF). The purpose of this study is investigating the feasibility of IFD with PLIF in the treatment of lumbar spondylolisthesis. Methods. Between September 2013 and November 2014, 39 patients underwent PLIF and subseque...

متن کامل

Biomechanical comparison of an interspinous device and a rigid stabilization on lumbar adjacent segment range of motion.

PURPOSE OF THE STUDY Decompression surgery with or without fusion is the gold standard treatment of lumbar spinal stenosis, but adjacent segment degeneration has been reported as a long-term complication after fusion. This led to the development of dynamic implants like the interspinous devices. They are supposed to limit extension and expand the spinal canal at the symptomatic level, but with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 2012