Comparison of pulmonary artery catheter, echocardiography, and arterial waveform analysis monitoring in predicting the hemodynamic state during and after cardiac surgery
نویسندگان
چکیده
OBJECTIVE The aim of this trial was to determine whether Flotrac Vigileo™ (FV™) provides a reliable representation of the hemodynamic state of a cardiac surgical patient population when compared to pulmonary artery catheter (PAC) and echocardiography in the peril-operative period. DESIGN This was a prospective observational trial comparing perioperative hemodynamic states using transesophageal echocardiography (TEE), transthoracic echocardiography (TTE), FV™ and PAC during and post cardiothoracic surgery. SETTING Tertiary regional hospital Intensive Care Unit (ICU). PARTICIPANTS 50 consecutive adult cardiothoracic patients with written consent provided. INTERVENTION Comparison of the perioperative hemodynamic states using echocardiography, FV™ and PAC was performed. Evaluation of the hemodynamic state (HDS) was performed using TEE, TTE, PAC and FV™ during and after cardiac surgery. Data were compared between the three hemodynamic assessment modalities. MAIN OUTCOME MEASURE Predicted hemodynamic state. RESULTS FV™ and PAC were shown to correlate poorly with TEE/TTE assessment of the hemodynamic state. Both PAC and FV™ showed significant discordance with echocardiographic assessment of the hemodynamic state. CONCLUSIONS In this trial, FV™ and PAC were shown to agree poorly with TTE/TEE assessment of the HDS in an adult cardiothoracic population. Agreement between the FV™ and PAC was also poor. Caution is recommended in interpreting isolated hemodynamic monitoring data. All hemodynamic monitoring devices have inherent sources of error. Caution is advised in interpreting any single device or measurement as a gold standard. We suggest that hemodynamic measuring devices such as FV™/PAC may act as triggers for a global hemodynamic assessment including consideration of TTE/TEE.
منابع مشابه
What's New in Critical Illness and Injury Science? The continued search for the ideal hemodynamic monitoring device: Spending ourselves in a worthy cause and coming up short
© 2017 International Journal of Critical Illness and Injury Science | Published by Wolters Kluwer Medknow The continued search for the ideal hemodynamic monitoring tool continues. Over time, the medical community has endeavored to identify correlates of hemodynamic status and resultant responses to volume expansion. Historically, we have pursued the use of physical examination alone (jugular he...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملContinuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs.
We developed a technique to continuously (i.e., automatically) monitor cardiac output (CO) and left atrial pressure (LAP) by mathematical analysis of the pulmonary artery pressure (PAP) waveform. The technique is unique to the few previous related techniques in that it jointly estimates the two hemodynamic variables and analyzes the PAP waveform over time scales greater than a cardiac cycle whe...
متن کاملثبات همودینامیک با کدام رژیم هوشبری در جراحی پیوند رگهای کرونر قلب بیماران تحت درمان با بتا-بلوکر بیشتراست؟سوفنتانیل سیس - آتراکوریوم یا سوفنتانیل-پانکرونیوم
Background and Aim: Hemodynamic stability during anesthesia and operation is the most important aim of anesthesiologists. Every anesthetic drug has its own hemodynamic effects. The interaction of these drugs with each other and with preoperative drugs of the patients, may cause critical changes in patient's hemodynamic status. For a perfect anesthesia induction, while using high doses of op...
متن کاملPulmonary artery rupture by the Swan-Ganz catheter: case report.
Pulmonary artery catheter is frequently used to monitor patients during liver transplantation. Recently developed less invasive methods for estimating cardiac output and pulmonary capillary wedge pressure together with the failure of randomized studies to demonstrate reduced mortality in pulmonary artery catheter-monitored patients, has restricted its applicability. Pulmonary artery rupture by ...
متن کامل