Effect of Storage Temperature on Bond Strength of a Self-Etch Adhesive System to Pulp Chamber Dentin

نویسندگان

  • Nazmiye Donmez
  • Hale Ari
  • Sema Belli
چکیده

OBJECTIVES The aim of this study was to evaluate the effect of storage temperature on bond strength of a self etching primer system to pulp chamber dentin. METHODS SE Bond (Kuraray, JAPAN) adhesive system and Clearfil Photo Posterior (Kuraray, JAPAN) composite resin were used. Eight extracted caries-free human molar teeth were used. Access cavities were prepared through the pulp chamber, randomly distributed into 4 groups and prepared as follows: Group 1 (Control): SE Primer and SE Bond (SEB) were applied to the pulp chamber dentin according to the manufacturer's instructions, immediately after the delivery from the manufacturer and then the pulp chamber was restored with a resin restorative material. The primer agent of the following groups was stored in a refrigerator and kept at 4 degrees C. Group 2: restored with SEB, kept at 4 degrees C refrigerator for 1 year, Group 3: restored with SEB kept at 23 degrees C room temperature for 1 year and Group 4: restored with SEB kept at 40 degrees C incubator for 1 year. After 24 hrs the teeth were trimmed for microtensile bond testing and loaded to failure at 1mm/min. Data were analyzed using one-way ANOVA and Duncan test (P<.05). RESULTS The results indicated that Group 4 showed lowest bond strength when compared to the others (P<.05). No statistically significant difference was found among the other groups (P>.05). CONCLUSIONS As a result of this study, it was concluded that increasing storing temperature or storing period decreases microtensile bond strength of a SEB system to pulp chamber dentin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bond durability of contemporary adhesive systems to pulp chamber dentin

Objective: The purpose of this study was to evaluate long-term bond strengths of dentin adhesive systems, which include one-step self-etch adhesive systems (Optibond All-in-one, Kerr; Adper Prompt L-POP, 3 M ESPE), a three-step etch-and-rinse adhesive (Optibond FL, Kerr) and two-step self-etch adhesive (AdheSE Bond, Ivoclar), applied to pulp chamber dentin surfaces after 12-month water storage ...

متن کامل

Sodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability

Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond&nbsp;strength (&micro;TBS) over time. Material & Methods: In this experimental study, 36 extracted &nbsp;third molars were used to evaluate the &micro;TBS of...

متن کامل

Strength and Durability of a New Adhesive Bond to Superficial Dentin Using Etch and Rinse and Self-Etch Systems: An In Vitro Study

Background and Aim: Data regarding the efficacy of universal adhesives are limited. This study aimed to assess the durability of a universal adhesive bond to superficial dentin using etch and rinse and self-etch modes. Materials and Methods: In this in vitro, experimental study, 32 sound molars were randomly divided into two groups of Scotchbond Universal adhesive with two-step etch and rins...

متن کامل

Comparative Evaluation of Microshear Bond Strength of 5th, 6th and 7th Generation Bonding Agents to Coronal Dentin Versus Dentin at Floor of Pulp Chamber: An In vitro Study

BACKGROUND Lack of seal and adhesion between the final restoration and tooth structure adversely affects the results of root canal treatment. Lots of adhesive bonding agents are marketed to overcome this deficiency and achieve successful restoration. So the study compares and evaluates the micro shear bond strength of coronal dentin and pulp chamber dentin using three different generation denti...

متن کامل

Shear bond strength of different adhesive systems to normal and caries-affected dentin

BACKGROUND AND AIM: According to the effect of the adhesive and substrate type on the bond strength, examination of the adhesive is required in all aspects. The aim of this study was to evaluate the shear bond strength of different adhesive systems to normal dentin (ND) and caries affected dentin (CAD) in permanent teeth. METHODS: Thirty extracted molars with small occlusal caries were selected...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2009