Ellipsometry with polarisation analysis at cryogenic temperatures inside a vacuum chamber.

نویسندگان

  • S Bauer
  • B Grees
  • D Spitzer
  • M Beck
  • R Bottesch
  • H-W Ortjohann
  • B Ostrick
  • T Schäfer
  • H H Telle
  • A Wegmann
  • M Zbořil
  • C Weinheimer
چکیده

In this paper we describe a new variant of null ellipsometry to determine thicknesses and optical properties of thin films on a substrate at cryogenic temperatures. In the PCSA arrangement of ellipsometry the polarizer and the compensator are placed before the substrate and the analyzer after it. Usually, in the null ellipsometry the polarizer and the analyzer are rotated to find the searched minimum in intensity. In our variant we rotate the polarizer and the compensator instead, both being placed in the incoming beam before the substrate. Therefore the polarisation analysis of the reflected beam can be realized by an analyzer at fixed orientation. We developed this method for investigations of thin cryogenic films inside a vacuum chamber where the analyzer and detector had to be placed inside the cold shield at a temperature of T ≈ 90 K close to the substrate. All other optical components were installed at the incoming beam line outside the vacuum chamber, including all components which need to be rotated during the measurements. Our null ellipsometry variant has been tested with condensed krypton films on a highly oriented pyrolytic graphite substrate (HOPG) at a temperature of T ≈ 25 K. We show that it is possible to determine the indices of refraction of condensed krypton and of the HOPG substrate as well as thickness of krypton films with reasonable accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ions in cold electrostatic storage devices Ions in cold electrostatic storage devices

We have constructed a compact purely electrostatic ion-beam trap, ConeTrap, which we have mounted inside a double-walled vacuum chamber. In the inner vacuum chamber, we can obtain ultra-high vacuum (UHV) conditions and reach thermal equilibrium at well controlled temperatures down to 10 K. The chamber was constructed partly with the purpose of making high-precision measurements in ConeTrap, but...

متن کامل

Measurements at Epa of Vacuum and Electron-cloud Related Effects

In the LHC, in addition to the molecular photodesorption due to synchrotron radiation, an electron cloud will produce a significant gas load due to electron stimulated desorption. This electron cloud build-up is strongly dependant on the primary photoelectrons, secondary electron production and on the reflectivity of photons and electrons. The dependence of these phenomena on surface properties...

متن کامل

A study of the operation of especially designed photosensitive gaseous detectors at cryogenic temperatures

In some experiments and applications there is need for large-area photosensitive detectors to operate at cryogenic temperatures. Nowadays, vacuum PMs are usually used for this purpose. We have developed special designs of planar photosensitive gaseous detectors able to operate at cryogenic temperatures. Such detectors are much cheaper than PMs and are almost insensitive to magnetic fields. Resu...

متن کامل

Advanced Tritium Recovery System

LLE Review, Volume 89 25 Introduction As part of the U.S. Inertial Confinement Fusion Program, LLE plans to implode deuterium–tritium (DT)–charged microspheres. These microspheres are filled with high-pressure deuterium and tritium gas under cryogenic conditions. The spheres are then stored and transferred as needed to the target chamber (located in an adjacent room) under vacuum and at tempera...

متن کامل

A cryogenic measurement setup for microelectromechanical systems used in space applications

We present a cryogenic measurement setup installed inside a focused-ion-beam sFIBd system to characterize and microrepair microelectromechanical systems sMEMSd for space applications. The setup allows testing of MEMS devices under vacuum condition of 10−6 Torr at variable temperatures ranging from 298 to 20 K. In the experiment, a lead-zirconate-titanate translator powered by a function generat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 84 12  شماره 

صفحات  -

تاریخ انتشار 2013