Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV γ-ray line from 57 Co, with a measured energy resolution of (8.8 ± 0.6)% (σ). The best achievable energy resolution, by removing the instrumental fluctuations, from liquid xenon scintillation light is estimated to be around 6-8% (σ) for γ-ray with energy between 662 keV and 122 keV.
منابع مشابه
s . in s - de t ] 3 A ug 2 00 6 Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
Scintillation light from gamma ray irradiations in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV γ-ray line from 57 Co, with a good...
متن کاملs . in s - de t ] 7 J ul 2 00 4 UT - ICEPP 04 - 02 Absorption of Scintillation Light in a 100 l Liquid Xenon γ Ray Detector and Expected Detector Performance
An 800 l liquid xenon scintillation γ ray detector is being developed for the MEG experiment which will search for μ → eγ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100 l prototype with an active volume of 372×372×496 mm to study the scintillation light absorption. We have devel...
متن کاملar X iv : a st ro - p h / 00 12 29 7 v 1 1 3 D ec 2 00 0 Spectroscopy and Imaging Performance of the Liquid Xenon Gamma - Ray Imaging Telescope ( LXeGRIT )
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic γ–rays in the energy band of 0.2-20 MeV. The detector, with 400 cm 2 area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual γ–ray inte...
متن کاملDevelopment of a liquid - xenon photon detector – – towards the search for a muon rare decay mode at Paul Scherrer Institute q
We are developing a new type of photon detector in preparation of an experiment to search for muons decaying into positrons and gamma rays. In the experiment, the photon detector will utilize liquid xenon (Xe) as the scintillation material because of its fast response, large light yield, and high density. The scintillation light emitted in liquid Xe will be observed directly by positioning phot...
متن کاملPreparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
We report the preparation of neutron-activated xenon for the calibration of liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable states, produced by fast neutron activation, were detected and their activities measured in a LXe scintillation detector. Following a five-day activation of natural xenon gas with a Cf (4× 10 n/s) source, the activities of two gamma ray lines at...