Efficacy and Safety of Cataract Extraction with Negative Power Intraocular Lens Implantation§

نویسندگان

  • Michael A Kapamajian
  • Kevin M Miller
چکیده

PURPOSE To evaluate the visual and refractive outcomes, lens power calculation accuracy, and safety of negative power intraocular lenses (IOLs) implanted in highly myopic eyes at the time of cataract surgery. DESIGN Interventional case series. METHODS Sixteen consecutive highly myopic eyes implanted with IOLs from -1 D to -6 D were identified. IOL power; preoperative and postoperative best-corrected visual acuity (BCVA); postoperative uncorrected visual acuity (UCVA); preoperative, intended, and achieved spherical equivalent (SE) refractive errors; and operative complications were recorded. RESULTS Median UCVA improved from finger counting to 20/50-2. Median BCVA improved from 20/125-1 to 20/30+1. Mean axial length was 32.65 mm. The mean SE refractive error was -22.19 ± 5.4 D before surgery and -0.28 ± 1.4 D after surgery. The difference between the mean intended and mean achieved SE refractive errors was +1.16 D for the SRK/T, +1.2 D for the Holladay 1, and +1.60 D for the Hoffer Q formulas. Only 5 (33.3%) of 15 eyes in which postoperative measurements were possible were within 1 D of the intended SE postoperative refraction. Postoperative complications included a mildly hyperopic postoperative refractive error (+1.75 D) in one eye necessitating an IOL exchange and posterior capsule opacification in most eyes. There were no retinal detachments. CONCLUSIONS The SRK/T formula had the greatest accuracy and predictability when immersion A-scan ultrasonography was used to measure axial length. The mean achieved postoperative refractive error was +1.16 D more hyperopic than predicted by this formula. We recommend targeting highly myopic eyes for -1.5 D using the SRK/T formula if a negative power IOL is calculated and emmetropia or mild residual myopia is the desired postoperative result.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation

The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...

متن کامل

Laser cataract surgery : A prospective clinical evaluation of 1000 consecutive laser cataract procedures using the Dodick photolysis Nd:YAG system.

BACKGROUND To evaluate the safety and efficacy associated with the clinical use of a Q-switched neodymium:yttrium-aluminum-garnet (ND:YAG) laser for cataract removal. DESIGN Multicenter, prospective, noncomparative case series. PARTICIPANTS/INTERVENTION A total of 1000 consecutive eyes underwent cataract extraction with the photolysis Q-switched ND:YAG laser at 12 international clinical sit...

متن کامل

Results of higher power toric intraocular lens implantation.

PURPOSE To evaluate the efficacy, predictability, and safety of coaxial microincision phacoemulsification and toric intraocular lens (IOL) implantation in eyes with high corneal astigmatism. SETTING Two eye clinics in Germany. DESIGN Case series. METHODS Routine cataract extraction using 2.2 mm coaxial phaco equipment and Acrysof toric IOL (3.00 to 6.00 diopters [D] cylinder) implantation...

متن کامل

Intraocular lens implantation in anterior megalophthalmus. Case report.

We report three cases of extracapsular cataract extraction with intraocular lens implantation in two patients with anterior megalophthalmus. This is the first report, to our knowledge, of intraocular lens implantation in this rare condition.

متن کامل

Simultaneous bilateral cataract extraction in the UK.

AIMS/BACKGROUND Simultaneous bilateral extracapsular cataract extraction (SBCE) is not routinely performed in the developed world. This study investigated the safety and efficacy of this procedure as performed in the UK. METHODS A review of 319 consecutive patients (638 eyes) who underwent SBCE with posterior chamber intraocular lens implantation is presented. RESULTS The incidence of intra...