Is portable three-dimensional ultrasound a valid technique for measurement of postpartum urinary bladder volume?

نویسندگان

  • Zalina Nusee
  • Norliza Ibrahim
  • Razman Mohd Rus
  • Hamizah Ismail
چکیده

OBJECTIVE To determine the accuracy of bladder volume (BV) measurement and to identify factors that influenced the ultrasound bladder scanner (UBS) measurement of BV in postpartum women compared with transurethral catheterization. MATERIALS, METHODS AND RESULTS A total of 190 paired measurements were performed on 190 women aged between 16 and 47 years. Majority of the women (36.9%) were in their first parity (range: 1-9). The mean BV was 159.46 mL [standard deviation (SD) = 99.78; range: 17-593 mL] on three-dimensional (3D) UBS and 143.76 mL (SD = 104.89; range: 2-588 mL) on catheterization. The mean difference between the two values was 15.70 mL (SD = 69.31, p < 0.001). The Foley's catheter was clamped for a minimum of 30 minutes and a maximum of 260 minutes. The UBS measurements were highly correlated with the BV obtained by catheterization (r = 0.819; p < 0.001). There was no significant difference between UBS and catheterized volume in a different volume subgroup. There were 35 cases (18.2%) with the difference in measurement of more than 25%. Twenty-five cases were associated with a catheterized volume less than 50 mL. There were a total of 33 cases with true BV of less than 50 mL, and only eight cases (24.24%) had an accurate measurement. The UBS tends to overestimate BV between 2 and 270 mL in this group. There was a significant linear relationship between the difference in measurement and body weight and duration of clamping. CONCLUSION Measurement of BV in immediate postpartum period using UBS is comparable with urethral catheterization. The accuracy of measurement is affected by body weight and increasing amount of BV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional ultrasonographic bladder volume measurement: reliability of the Virtual Organ Computer-Aided Analysis technique using different rotation steps.

OBJECTIVE The purpose of this study was to investigate the reliability of Virtual Organ Computer-Aided Analysis (VOCAL; GE Healthcare, Kretztechnik, Zipf, Austria) using the 4 standard rotation steps to measure the bladder volume with 3-dimensional (3D) ultrasonography. METHODS Using the 4 standard rotation steps of VOCAL, 2 independent observers made 3D volume measurement data sets from the ...

متن کامل

Prevalence of postoperative bladder distension and urinary retention detected by ultrasound measurement.

BACKGROUND Postoperative bladder distension and urinary retention are commonly underestimated. Ultrasound enables accurate measurement of bladder volume and thus makes it possible to determine the prevalence of postoperative bladder distension. METHODS Using ultrasound, we measured the volume of the bladder contents at the time of discharge from the recovery room in 177 adult patients who had...

متن کامل

Three-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs

Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...

متن کامل

Comparison between bladderscan, real-time ultrasound and suprapubic catheterisation in the measurement of female residual bladder volume.

Hypothesis / aims of study The measurement of residual urine is an essential part of the management of many urogynaecological patients such as patients with voiding difficulties before or after surgical intervention, patients with neurogenic bladders or dysfunctional voiding. Bladder residual volume has been historically measured by urethral or suprapubic catheterisation and is still considered...

متن کامل

Is Foley Catheter Able to Drain the Bladder Completely in the Morning for Patients in ICU?

Introduction: Foley catheters are assumed to drain the bladder completely. It is known that uncompleted drainage leads to multiple complications, such as asymptomatic bacteriuria and urinary tract infection. Methods: From 116 patients, who were admitted to intensive care unit (ICU) for more than 24 hours, were enrolled in this study. To measure the urine level in bladder in the morning before a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Taiwanese journal of obstetrics & gynecology

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2014