New insights into hard phases of CoCrMo metal-on-metal hip replacements.

نویسندگان

  • Y Liao
  • R Pourzal
  • P Stemmer
  • M A Wimmer
  • J J Jacobs
  • A Fischer
  • L D Marks
چکیده

The microstructural and mechanical properties of the hard phases in CoCrMo prosthetic alloys in both cast and wrought conditions were examined using transmission electron microscopy and nanoindentation. Besides the known carbides of M(23)C(6)-type (M=Cr, Mo, Co) and M(6)C-type which are formed by either eutectic solidification or precipitation, a new mixed-phase hard constituent has been found in the cast alloys, which is composed of ∼100 nm fine grains. The nanosized grains were identified to be mostly of M(23)C(6) type using nano-beam precession electron diffraction, and the chemical composition varied from grain to grain being either Cr- or Co-rich. In contrast, the carbides within the wrought alloy having the same M(23)C(6) structure were homogeneous, which can be attributed to the repeated heating and deformation steps. Nanoindentation measurements showed that the hardness of the hard phase mixture in the cast specimen was ∼15.7 GPa, while the M(23)C(6) carbides in the wrought alloy were twice as hard (∼30.7 GPa). The origin of the nanostructured hard phase mixture was found to be related to slow cooling during casting. Mixed hard phases were produced at a cooling rate of 0.2 °C/s, whereas single phase carbides were formed at a cooling rate of 50 °C/s. This is consistent with sluggish kinetics and rationalizes different and partly conflicting microstructural results in the literature, and could be a source of variations in the performance of prosthetic devices in-vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CoCrMo metal-on-metal hip replacements.

After the rapid growth in the use of CoCrMo metal-on-metal hip replacements since the second generation was introduced circa 1990, metal-on-metal hip replacements have experienced a sharp decline in the last two years due to biocompatibility issues related to wear and corrosion products. Despite some excellent clinical results, the release of wear and corrosion debris and the adverse response o...

متن کامل

Microstructure of Retrievals Made from Standard Cast HC-CoCrMo Alloys

During the past decade, self-mating metal bearings based on cobalt– chromium–molybdenum (CoCrMo) alloys have become very popular in total hip replacements and hip resurfacings. This led to a market share of more than 35 % for metal-on-metal (MoM) bearings in the United States before several cases of high wear with biologic consequences led to a sharp drop in popularity. In part, these failures ...

متن کامل

An Investigation of LENS®-Deposited Medical-Grade CoCrMo Alloys

A series of deposition experiments using CoCrMo were performed using an Optomec LENS® machine. An analysis of hardness, microstructure, and wear trends of the deposited alloys was undertaken in an attempt to determine the applicability of using LENS® to create better materials for orthopedic implants. It was found that LENS®-deposited CoCrMo alloys were harder than wrought materials, however in...

متن کامل

Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: An in vitro study.

Wear and corrosion at the modular head-neck junction has been recognised to be a potential clinical concern, with multiple reports on adverse local tissue reactions and subsequent early failure of metal-on-metal hip replacements. Furthermore, reports on head-neck taper corrosion are also being described with conventional metal-on-polyethylene bearings. Manufacturing tolerances, surgical techniq...

متن کامل

Tribological performance of various CoCr microstructures in metal-on-metal bearings: the development of a more physiological protocol in vitro.

Hip simulators have been used for ten years to determine the tribological performance of large-head metal-on-metal devices using traditional test conditions. However, the hip simulator protocols were originally developed to test metal-on-polyethylene devices. We have used patient activity data to develop a more physiologically relevant test protocol for metal-on-metal devices. This includes sto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012