Intraoperative centration during small incision lenticule extraction (SMILE)

نویسندگان

  • John X. Wong
  • Elizabeth P. Wong
  • Hla M. Htoon
  • Jodhbir S. Mehta
چکیده

To evaluate intraoperative decentration from pupil center and kappa intercept during small incision lenticule extraction (SMILE) and its impact on visual outcomes.This was a retrospective noncomparative case series. A total of 164 eyes that underwent SMILE at the Singapore National Eye Center were included. Screen captures of intraoperative videos were analyzed. Preoperative and 3 month postoperative vision and refractive data were analyzed against decentration.The mean preoperative spherical equivalent (SE) was -5.84 ± 1.77. The mean decentration from the pupil center and from kappa intercept were 0.13 ± 0.06 mm and 0.47mm ± 0.25 mm, respectively. For efficacy and predictability, 69.6% and 95.0% of eyes achieved a visual acuity (VA) of 20/20 and 20/30, respectively, while 83.8% and 97.2% of eyes were within ±0.5D and ±1.0D of the targeted SE. When analyzed across 3 groups of decentration from the pupil center (<0.1 mm, 0.1-0.2 mm, and >0.2 mm), there was no statistically significant association between decentration, safety, efficacy, and predictability. When analyzed across 4 groups of decentration from kappa intercept (<0.2 mm, 0.2-<0.4 mm, 0.4-<0.6 mm, and ≥0.6 mm), there was a trend toward higher efficacy for eyes with decentration of kappa intercept between 0.4 and <0.6 mm (P = .097). A total of 85.4% of eyes in the 0.4 to <0.6 mm group had unaided distance VA of 20/20 or better, as compared to only 57.8% of eyes in ≥0.6 mm group.Decentration of 0.13 mm from the pupil center does not result in compromised visual outcomes. Decentration of greater than 0.6 mm from the kappa intercept may result in compromised visual outcomes. There was a trend toward better efficacy in eyes which had decentered treatment from 0.4 to <0.6 mm from the kappa intercept. Patients with a large kappa intercept (>0.6 mm) should have their lenticule created 0.4 to 0.6 mm from the kappa intercept and not close to the pupil.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small incision lenticule extraction (SMILE) in the correction of myopic astigmatism: outcomes and limitations - an update

Small Incision Lenticule Extraction (SMILE) is a flap-free intrastromal technique for the correction of myopia and myopic astigmatism. To date, this technique lacks automated centration and cyclotorsion control, so several concerns have been raised regarding its capability to correct moderate or high levels of astigmatism. The objective of this paper is to review the reported SMILE outcomes for...

متن کامل

New Instruments for Lenticule Extraction in Small Incision Lenticule Extraction (SMILE)

Small incision lenticule extraction (SMILE) is an alternative to Laser-Assisted in situ Keratomileusis (LASIK) for correction of myopia. In cases where surgeons inadvertently dissect the posterior surface first, identification of the anterior surface and subsequent removal become difficult since the anterior surface of the lenticule is compacted against the anterior stromal surface. This may re...

متن کامل

Management of incision failure during small incision lenticule extraction because of conjunctivochalasis

Purpose We report a case of incision failure during small incision lenticule extraction (SMILE) and its management. Observations The incision could not be made using the femtosecond laser because of a redundant conjunctiva, so it was instead done manually using a diamond knife. The lenticule was successfully separated and extracted. Three months after the procedure, the uncorrected distance v...

متن کامل

Changes in Corneal Deformation Parameters after Lenticule Creation and Extraction during Small Incision Lenticule Extraction (SMILE) Procedure

PURPOSE To investigate the effects of lenticule creation and subsequent corneal lenticule extraction on corneal deformation parameters during small incision lenticule extraction (SMILE) procedure. MATERIALS AND METHODS In this prospective study, 18 eyes of 10 patients (27.90 ± 7.11 years, -5.64 ± 2.45 diopters) scheduled for SMILE procedure were enrolled. Changes in the corneal deformation pa...

متن کامل

Small incision lenticule extraction (SMILE) in 2015.

Small incision lenticule extraction (SMILE) represents a recent addition to the refractive surgeon's range of procedures. Although there remains a number of similarities to existing techniques in terms of patient selection and treatment parameters, consideration is required to optimise patient outcomes and satisfaction. Here, we review the selection criteria, contraindications, indications and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017