Comparison of two methods of goniometry.
نویسنده
چکیده
This investigation was conducted to determine if there are significant differences between the lateral and the over-the-joint methods of goniometry for measurements of the elbow joint. Forty physical therapy students with previous goniometric training were divided randomly into four goniometric measurement groups: 1) lateral method for an obtuse angle, 2) lateral method for an acute angle, 3) over-the-joint method for an obtuse angle, and 4) over-the-joint method for an acute angle. All students in each group participated in four sessions during which a proctor's elbow joint was measured according to the method of the assigned goniometric measurement group. The joint was held in a fixed position by a plywood stabilizing device. The results of a three-factor analysis of variance with repeated measures on one factor showed that there was no difference between the lateral and the over-the-joint methods of goniometric measurement of the elbow joint.
منابع مشابه
Validation of Goniometric Method in the Assessment of Lordosis by Radiographic Analysis
Background & Aims: Cervical spine is prone to various abnormalities and sport injuries. There is still no non-aggressive measurement instrument with high reliability for easy and rapid assessment of cervical spine secondary complications. The aim of this research was to investigate the validity of goniometric method for cervical lordosis measurement through radiography. Method: In this study, 1...
متن کاملMeasuring the Quadriceps Angle by a New Method and Comparison with Goniometer and Radiography
Objective: The purpose of this study is to decrease the amount of error when measuring Q–angles using a goniometer by the new method, a private system developed at the I.R;#39s university of social welfare & rehabilitation sciences (USWR) by Investigator. Materials & Methods: Fourty subjects with Eighty healthy knees participated in this methodologic study. One investigator participated in d...
متن کاملAnalysis of the reliability and reproducibility of goniometry compared to hand photogrammetry
OBJECTIVE To evaluate the intra- and inter-examiner reliability and reproducibility of goniometry in relation to photogrammetry of hand, comparing the angles of thumb abduction, PIP joint flexion of the II finger and MCP joint flexion of the V finger. METHODS The study included 30 volunteers, who were divided into three groups: one group of 10 physiotherapy students, one group of 10 physiothe...
متن کاملA comparison of hallux valgus angles assessed with computerised plantar pressure measurements, clinical examination and radiography in patients with diabetes
BACKGROUND Hallux valgus deformity is a common musculoskeletal foot disorder with a prevalence of 3.5% in adolescents to 35.7% in adults aged over 65 years. Radiographic measurements of hallux valgus angles (HVA) are considered to be the most reproducible and accurate assessment of HVA. However, in European countries, many podiatrists do not have direct access to radiographic facilities. Theref...
متن کاملThe reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometer.
This study investigated the reliability and concurrent validity of active shoulder elevation in the scapular plane (scaption) using a digital inclinometer and goniometer. Two investigators used a goniometer and digital inclinometer to measure scaption on 30 asymptomatic participants in a blinded repeated measures design. Good reliability was present with intraclass correlation coefficients (ICC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical therapy
دوره 63 6 شماره
صفحات -
تاریخ انتشار 1983