Comparison Of Gait Biomechanics Between Kinematically Aligned And Neutrally Aligned Total Knee Arthroplasty

نویسندگان

  • Takeo Nagura
  • Yasuo Niki
  • Kengo Harato
  • Yoshiaki Toyama
  • Yasunori Suda
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design.

BACKGROUND Kinematically aligned total knee arthroplasty (TKA) is of increasing interest because this method might improve postoperative patient satisfaction. In kinematic alignment the femoral component is implanted in a slightly more valgus and internally rotated position, and the tibial component is implanted in a slightly more varus and internally rotated position, than in mechanical alignm...

متن کامل

Differences in pediatric vertical ground reaction force between planovalgus and neutrally aligned feet.

Ground reaction forces (GRF) reflect the force history of human body contact with the ground. The purpose of this study was to explore human gait abnormalities due to planovalgus by comparing vertical GRF data between individuals with planovalgus and those with neutrally aligned feet. Second we estimated associations between various measurements and vertical GRF parameters in a pediatric popula...

متن کامل

Kinematically versus mechanically aligned total knee arthroplasty.

The purpose of this study was to compare 2 alignment methods for total knee arthroplasty (TKA): kinematic alignment with the use of patient-specific guides and mechanical alignment with conventional instruments. A randomized, controlled trial of 41 kinematically aligned and 41 mechanically aligned patients was conducted with the patient, radiographic evaluator, and clinical evaluator blinded to...

متن کامل

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Three-dimensional analysis of the tibial resection plane relative to the arthritic tibial plateau in total knee arthroplasty

BACKGROUND Kinematically aligned total knee arthroplasty strives to correct the arthritic deformity by restoring the native tibial joint line. However, the precision of such surgical correction needs to be quantified in order to reduce recuts of the resection and to design assisting instrumentation. This study describes a method for novel three-dimensional analysis of tibial resection parameter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015