A CUDA Monte Carlo simulator for radiation therapy dosimetry based on Geant4
نویسندگان
چکیده
1 Institute for Computational & Mathematical Engineering, Stanford University, 475 Via Ortega, Stanford, CA 94306, USA 2 High Energy Accelerator Research Organization, KEK, 1-1 Oho, Tsukuba, Ibaraki, 305-0801, JAPAN SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA Electrical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka, Niigata, 940-2188, JAPAN Ashikaga Institute of Technology, 268-1 Omae-cho, Ashikaga, Tochigi, 326-8558 JAPAN Kobe University, 1-1 Rokkodai-cho, Nada-ku, Kobe 657-8501, JAPAN * Corresponding Author, E-mail: [email protected]
منابع مشابه
Radioiodine (131-I) treatment for Graves’ disease: Geant4 Monte Carlo simulation for patient personalized dose estimation
Background: Reliable estimation of radiation-absorbed dose is necessary to evaluate the benefits and the risks of radiopharmaceuticals used for diagnostic or therapeutic purposes in nuclear medicine. Materiel and Methods: This study included 47 patients treated with iodine-131 for Graves’ disease. A comparative study between Geant4 Monte Carlo simulation and MIRD formalism was carried out to ev...
متن کاملEvaluation of cellular S-value of auger electrons emitting 111In radionuclide by Geant4 and its comparison with MCNP5 Monte Carlo codes and MIRD published data
Introduction: Now day Ionizing radiation has found increasing applications in cancer treatment. However, in the treatment different kinds and size of tumors especially metastatic and small size tumors, conventional methods of external radiation therapy are not common. In radionuclide therapy, the use of monoclonal antibodies has made it possible to achieve maximum dose to small size tumor and m...
متن کاملProtons & Carbon Therapy
Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...
متن کاملA review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications.
In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy,...
متن کاملA Microdosimetry model of kidney for nephrotoxicity due to internal radiation therapy
Introduction: We describe a nephron-based dosimetry model for renal toxicity for radiopharmaceutical therapy suited to the nonuniform activity distribution of radiopharmaceutical. In radiopharmaceutical therapy, renal toxicity is observed while whole-kidney and renal cortex absorbed dose values are below toxicity thresholds established by external beam and targeted radiope ptid...