Comments on extrapolation of cancer response from high dose to low dose.
نویسنده
چکیده
In making judgments as to the cancer risk from low level exposure to carcinogens it is generally necessary to base these judgments on high dose or high incidence data from laboratory or epidemiological studies. The biological considerations involved in making such extrapolations are discussed, as well as some of the mathematical procedures. The difficulties presented by moving from species to species, or from differently acting carcinogenic agents is considered.
منابع مشابه
Study of cancer cells response row K562 to Low-Dose- Beta irradiation and determination of absorbed dose using Monte Carlo method
Introduction: Cancer is, in essence, a genetic disease and is the second leading cause of death globally. Fortunately, many common types of cancer are treatable if detected early and of course there are many medications and treatments available today. Among the new methods to treat cancer, radiotherapy seems to be hopeful in patients with malignancies. This work investigates th...
متن کاملBasic investigation on performance of low-density polymer gel dosimeter
Background: In this study a series of basic dosimetric properties of a low-density (LD) gel dosimeter are investigated. The dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. Materials and Methods: The LD gel was made by mixing the polymer gel with expanded polystyrene spheres. Energy dependence was studied...
متن کاملIntermittent low dose irradiation enhances the effectiveness of radio-therapy for human breast adenocarcinoma cell line MDA–MB–231
Introduction: Hormesis and adaptive responses are two important biological effects of low-dose ionizing radiation (LDIR) in organism and mammalian cell lines. Notably, LDIR generates distinct biological effects in cancer cells from normal cells, e.g., it may affect the growth of cancer cells via the activation of certain cell signaling pathway, which does not exist in normal ...
متن کاملDose measurement outside of radiotherapy treatment field (Peripheral dose) using thermoluminesent dosimeters
Background: In radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. One of these critical organs in pelvic irradiation is testis. The amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. The threshol...
متن کاملNon-linear phenomena in biological findings of the residents of high background radiation areas of Ramsar
Some Areas of Ramsar, a city in northern Iran are among the world’s wellknown inhabited areas with highest levels of natural radiation. Annual exposure levels in these areas are up to 260 mGy y‐1 and the mean exposure rate is about 10 mGy y‐1 for a population of about 2000 residents. If elevated levels of natural radiation as high as a few hundred mSv per year is detrimental to health and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental Health Perspectives
دوره 22 شماره
صفحات -
تاریخ انتشار 1978