Impedance Matching Based Control for the Resonance Damping of Microgrids with Multiple Grid Connected Converters
نویسندگان
چکیده
This paper presents an impedance-matching-based control scheme for the harmonic resonance damping of multiple grid-connected-converters (GCCs) with LCL filters. As indicated in this paper, harmonic resonance occurs if a GCC possesses an output impedance that is not matched with the rest of the network in some specific frequency bands. It is also revealed that the resonance frequency is associated with the number of GCCs, the grid impedance and even the capacitive loads. By controlling the grid-side current instead of the converter-side current, the critical LCL filter is restricted as an internal component. Thus, the closed-loop output impedance of the GCC within the filter can be configured. The proposed scheme actively regulates the output impedance of the GCC to match the impedance of the external network, based on the detected resonance frequency. As a result, the resonance risk of multiple GCCs can be avoided, which is beneficial for the plug-and-play property of the GCCs in microgrids. Simulation and experimental results validate the effectiveness of the proposed method.
منابع مشابه
Stability Improvement of Grid-connected Converter with LCL Filter based on Capacitor Current Active Damping by Computational Delay Reduction
Nowadays, LCL filters utilization to suppress the grid-connected inverter switching harmonics is expanding and various methods such as capacitor current active damping scheme could be investigated to damp out these harmonics. However, the computational delays including control system, and PWM switching delays have significant effect on damping system stability. In most of LCL filter parameter d...
متن کاملA Repetitive Control- based Approach for Power Sharing among Boost Converters in DC Microgrids
In this paper a repetitive control (RC) approach to improve current sharing between parallel-connected boost converters in DC microgrids is presented. The impact of changes in line impedance on current sharing is investigated. A repetitive controller is designed and connected in series with current controller of the boost converters to control the switching signals such that by regulating of th...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملGrid impedance estimation based hybrid islanding detection method for AC microgrids
This paper focuses on a hybrid islanding detection algorithm for parallel-inverters-based microgrids. The proposed algorithm is implemented on the unit ensuring the control of the intelligent bypass switch connecting or disconnecting the microgrid from the utility. This method employs a grid impedance estimation technique that uses resonance excitation once grid fault occurs. It includes two st...
متن کاملApplication of the Min-Projection and the Model Predictive Strategies for Current Control of Three-Phase Grid-Connected Converters: a Comparative Study
This paper provides a detailed comparative study concerning the performance of min-projection strategy (MPS) and model predictive control (MPC) systems to control the three-phase grid connected converters. To do so, first, the converter is modeled as a switched linear system. Then, the feasibility of the MPS technique is investigated and its stability criterion is derived as a lower limit on th...
متن کامل