Validation of Heine Gamma G7 (G5) and XXL-LF aneroid devices for blood pressure measurement.

نویسندگان

  • Francesca Dorigatti
  • Elisa Bonso
  • Ada Zanier
  • Paolo Palatini
چکیده

OBJECTIVE To determine the accuracy of the Gamma G7 (and G5 model) and XXL-LF aneroid sphygmomanometers developed by the Heine Company. DESIGN Device evaluations were performed using the new protocol of the European Society of Hypertension. Monitor performance was assessed in relation to participants' sex, age, arm circumference, and systolic and diastolic blood pressures. METHODS The two sphygmomanometers were assessed in two different samples according to European Society of Hypertension requirements, which are based on four zones of accuracy differing from the mercury standard by 5, 10, 15 mmHg, or more. RESULTS Both sphygmomanometers passed all three phases of the protocol for systolic blood pressure and diastolic blood pressure. Mean blood pressure difference between Gamma G7 sphygmomanometer and observers was -0.4+/-3.3 mmHg for systolic blood pressure and -0.5+/-2.6 mmHg for diastolic blood pressure. Mean differences for the Gamma XXL-LF sphygmomanometer were -0.3+/-3.7 and -1.0+/-2.6 mmHg, respectively. In multivariable analyses, the SBP discrepancies between both aneroid sphygmomanometers and observers were unrelated to age, sex, arm circumference and systolic blood pressure. For diastolic blood pressure, a borderline relationship was found only for arm circumference (P=0.057) with the Gamma G7 device. CONCLUSIONS These data show that the Heine Gamma G7 and Gamma XXL-LF aneroid sphygmomanometers satisfy the new recommended ESH accuracy levels for both SBP and DBP. Their performance is uniform across subgroups of participants with different clinical characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standards for blood pressure measuring devices.

In 1985 the British Hypertension Society established a working party on blood pressure measurement to make recommendations on the technique of measurement, and the recommendations have now been published.' The working party was also asked to improve the accuracy of measuring devices and examine the feasibility of providing minimal standards for all such devices. The introduction and enforcement...

متن کامل

Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors?

OBJECTIVES To compare the agreement between conventional measurement of blood pressure and measurements obtained using two automated devices; and to compare how comfortable each of the three methods of measurement were for patients. METHODS Blood pressure measurements and patient comfort scores were recorded using three different devices in 125-surgery and 40-community patients. The devices u...

متن کامل

Evaluating the accuracy of an aneroid sphygmomanometer in a clinical trial setting.

BACKGROUND The mercury sphygmomanometer, the "gold" standard for blood pressure measurements, has been gradually phased out in many institutions because of environmental concerns. Our on-going clinical trial compared the use of mercury vs. aneroid sphygmomanometers, before implementing a study-wide transition to the aneroid sphygmomanometer. METHODS The Diabetes Prevention Program Outcomes St...

متن کامل

Comparison of aneroid and oscillometric blood pressure measurements in children.

Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and oscillometric devices. The purpose of the study was to investigate the difference in BP obtained using oscillometric and aneroid BP monitors in 9- to 10-year-old children. A total of 979 children were divided into group O, which underwent two oscillometric BP readings followed by two aneroid readings, and...

متن کامل

Validation of Missouri aneroid sphygmomanometer to measure blood pressure in patients with cancer.

BACKGROUND Auscultatory mercury sphygmomanometers to measure blood pressure (BP) have been banned from health services because of risk of pollution and environmental accidents with mercury. Aneroid appliances could be an alternative. OBJECTIVE To validate the Missouri aneroid device for blood pressure measurement in cancer patients according to the protocol of the European Society of Hyperten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood pressure monitoring

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 2007