Self-monitoring of blood glucose levels requires intensive training for use of meters to obtain reliable and clinically relevant measurements.

نویسندگان

  • Thomas A Mohr
  • Andreas Pfützner
  • Senait Forst
  • Thomas Forst
  • Thomas Schöndorf
چکیده

BACKGROUND Anecdotal reports from pediatric sites have indicated that some blood glucose meters may display wrong and misleading numbers rather than error indications, when operated in deviation from the instructions for use (IFU), eg by manipulating the strip during the count-down phase. METHODS This study was performed with 60 patients with diabetes (32 female, 28 male, 21 type 1, 39 type 2, age (mean+/-SD): 56+/-11 years) who measured their blood glucose levels twice with five different blood glucose meters (Precision(R) Xceed [Abbott Medisense], Freestyle Mini [Abbott Medisense], Accu-Chek Comfort [Roche Diagnostics], Accu-Chek Aviva [Roche Diagnostics], and Ascensia Contour [Bayer Vital]). The first measurement was performed in accordance with the IFU, and the second by manipulating the test strip using a standardised inflexion/release procedure during the count-down phase. A standard glucose oxidase method (SuperGL) served as laboratory reference. RESULTS All meters worked in full compliance with current accuracy standards when operated according to the IFU. When manipulating the test strip, the results varied considerably: While changes in reliability were acceptable for two devices (Precision Xceed, Freestyle Mini), the other devices produced an unacceptable number of errors and a series of entirely wrong values without error indication. CONCLUSIONS The use of all devices is recommended when used according to the IFU. The use under the artificially induced impaired testing conditions is a major concern. This study underlines the importance of appropriate patient training regarding adherence to the IFU of glucose meters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-Invasive Determination of Blood Glucose Levels by Optical Waveguide

Objective: Today, there are various non-invasive techniques available for the determination of blood glucose levels. In this study, the level of blood glucose was determined by developing a new device using near-infrared (NIR) wavelength, glass optical waveguide, and the phenomenon of evanescent waves. Materials and Methods: The body's interstitial fluid has made possible the development of ne...

متن کامل

Assessment of three frequently used blood glucose monitoring devices in clinical routine.

BACKGROUND Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aime...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Tight glucose control in critically ill patients: should glucose meters be used?

Measurement of blood glucose concentrations using portable, hand-held meters is used widely in patients with diabetes. Clinical settings include self-monitoring of blood glucose by patients, in doctors’ offices, in chronic care facilities, and in hospitals. More recently, evidence has emerged suggesting that tight glycemic control of nondiabetic patients in hospital intensive care units (ICUs) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2007