Time-resolved fluorescence anisotropy imaging applied to live cells.
نویسندگان
چکیده
We have developed a wide-field time-resolved imaging system to image quantitatively both the fluorescence lifetime and the rotational correlation time of a fluorophore. Using a polarization-resolved imager, we simultaneously image orthogonal polarization components of the fluorescence emission onto a time-gated intensified CCD. We demonstrate imaging of solvent viscosity variations through the rotational correlation time of fluorescein in a multiwell plate and apply this technique to probe the microviscosity in live cells.
منابع مشابه
Steady-State Acceptor Fluorescence Anisotropy Imaging under Evanescent Excitation for Visualisation of FRET at the Plasma Membrane
We present a novel imaging system combining total internal reflection fluorescence (TIRF) microscopy with measurement of steady-state acceptor fluorescence anisotropy in order to perform live cell Förster Resonance Energy Transfer (FRET) imaging at the plasma membrane. We compare directly the imaging performance of fluorescence anisotropy resolved TIRF with epifluorescence illumination. The use...
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملHomo-FRET Based Biosensors and Their Application to Multiplexed Imaging of Signalling Events in Live Cells
Multiplexed imaging of Förster Resonance Energy Transfer (FRET)-based biosensors potentially presents a powerful approach to monitoring the spatio-temporal correlation of signalling pathways within a single live cell. Here, we discuss the potential of homo-FRET based biosensors to facilitate multiplexed imaging. We demonstrate that the homo-FRET between pleckstrin homology domains of Akt (Akt-P...
متن کاملOligomerization of the serotonin(1A) receptor in live cells: a time-resolved fluorescence anisotropy approach.
The serotonin(1A) receptor is a representative member of the G-protein coupled receptor (GPCR) superfamily and serves as an important target in the development of therapeutic agents for neuropsychiatric disorders. Oligomerization of GPCRs is an important contemporary issue since it is believed to be a crucial determinant for cellular signaling. In this work, we monitored the oligomerization sta...
متن کاملTime-resolved fluorescence polarization dynamics and optical imaging of Cytate: a prostate cancer receptor-targeted contrast agent.
Cypate-octreote peptide analogue conjugate (Cytate) was investigated as a prostate cancer receptor-targeted contrast agent. The absorption and fluorescence spectra of Cytate were ranged in the near-infrared "tissue optical window." Time-resolved investigation of polarization-dependent fluorescence emitted from Cytate in solution as well as in cancerous and normal prostate tissues was conducted....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 29 6 شماره
صفحات -
تاریخ انتشار 2004