Dynamic functional residual capacity can be estimated using a stress-strain approach

نویسندگان

  • Ashwath Sundaresan
  • J. Geoffrey Chase
  • Christopher E. Hann
  • Geoffrey M. Shaw
چکیده

BACKGROUND Acute Respiratory Distress Syndrome (ARDS) results in collapse of alveolar units and loss of lung volume at the end of expiration. Mechanical ventilation is used to treat patients with ARDS or Acute Lung Injury (ALI), with the end objective being to increase the dynamic functional residual capacity (dFRC), and thus increasing overall functional residual capacity (FRC). Simple methods to estimate dFRC at a given positive end expiratory pressure (PEEP) level in patients with ARDS/ALI currently does not exist. Current viable methods are time-consuming and relatively invasive. METHODS Previous studies have found a constant linear relationship between the global stress and strain in the lung independent of lung condition. This study utilizes the constant stress-strain ratio and an individual patient's volume responsiveness to PEEP to estimate dFRC at any level of PEEP. The estimation model identifies two global parameters to estimate a patient specific dFRC, β and mβ. The parameter β captures physiological parameters of FRC, lung and respiratory elastance and varies depending on the PEEP level used, and mβ is the gradient of β vs. PEEP. RESULTS dFRC was estimated at different PEEP values and compared to the measured dFRC using retrospective data from 12 different patients with different levels of lung injury. The median percentage error is 18% (IQR: 6.49) for PEEP=5 cmH₂O, 10% (IQR: 9.18) for PEEP=7 cmH₂O, 28% (IQR: 12.33) for PEEP=10 cmH₂O, 3% (IQR: 2.10) for PEEP=12 cmH₂O and 10% (IQR: 9.11) for PEEP=15 cmH₂O. The results were further validated using a cross-correlation (N=100,000). Linear regression between the estimated and measured dFRC with a median R² of 0.948 (IQR: 0.915, 0.968; 90% CI: 0.814, 0.984) over the N=100,000 cross-validation tests. CONCLUSIONS The results suggest that a model based approach to estimating dFRC may be viable in a clinical scenario without any interruption to ventilation and can thus provide an alternative to measuring dFRC by disconnecting the patient from the ventilator or by using advanced ventilators. The overall results provide a means of estimating dFRC at any PEEP levels. Although reasonable clinical accuracy is limited to the linear region of the static PV curve, the model can evaluate the impact of changes in PEEP or other mechanical ventilation settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Residual Stress for Single and Double Autofrettage of Thick-walled FG Cylinders Subjected to Dynamic Loading

In the present article a numerical procedure is developed for dynamic analysis of single and double autofrettage of thick–walled FG cylinders under transient loading. The governing differential equations are discretized and presented in explicit Lagrangian formalism. The explicit transient solution of discrete equations are obtained on the meshed region and results for stress and strain distrib...

متن کامل

Numerical Solution of Seismic Wave Propagation Equation in Uniform Soil on Bed Rock with Weighted Residual Method

To evaluate the earth seismic response due to earthquake effects, ground response analyses are used to predict ground surface motions for development of design response spectra, to compute dynamic stresses and strains for evaluation of liquefaction hazards, and to determine the earthquake induced forces that can lead to instability of earth and earth-retaining structures. Most of the analytical...

متن کامل

Numerical Study of the Effect of Materials’ Plastic Behavior on Equibiaxial Residual Stress Measurement Using Indentation

Indentation is a new method for estimating residual stress. The plastic behavior of the materials under study can affect indentation parameters and, thus, influences the results of residual stress measurement. In this paper, the effect of yield stress and work-hardening exponent on the accuracy of residual stress measurements in steels and aluminums was studied. Results showed that, for m...

متن کامل

Are There Any Differences in Seismic Performance Evaluation Criteria for Concrete Arch Dams?

Differences between stress-based and strain-based criteria are investigated in seismic performance evaluation of the arch dams in time domain. A numerical model of the coupled dam-reservoir-foundation system is prepared with the finite element technique. Reservoir is modeled using the Eulerian approach as a compressible domain, and the foundation rock is assumed to be massless. Dynamic equilibr...

متن کامل

Analysis of different model-based approaches for estimating dFRC for real-time application

BACKGROUND Acute Respiratory Distress Syndrome (ARDS) is characterized by inflammation, filling of the lung with fluid and the collapse of lung units. Mechanical ventilation (MV) is used to treat ARDS using positive end expiratory pressure (PEEP) to recruit and retain lung units, thus increasing pulmonary volume and dynamic functional residual capacity (dFRC) at the end of expiration. However, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 101 2  شماره 

صفحات  -

تاریخ انتشار 2011