Scanning electron microscopic study of monofilament suture knots.
نویسندگان
چکیده
AIMS/BACKGROUND Interrupted corneal sutures are used routinely by many cataract and corneal surgeons. A slim compact knot facilitates burial and allows atraumatic suture removal, with decreased risk of wound dehiscence. The size and morphology of knots tied in different configurations were investigated. METHODS 10-0 nylon suture material was used to tie knots on porcine corneal cataract sections using 2/1/1 (reef and granny), 3/1/1, and 1/1/1/1 (slip knot) configurations. 10-0 Mersilene was used to tie 2/1/1 reef knots. Scanning electron micrographs of the knots were digitised and their maximal lengths and widths estimated. In addition, the area of each knot was calculated and used as an index of its volume. RESULTS 2/1/1 reef knots were significantly smaller in all dimensions compared with the other knots (all p < 0.03) except for the maximal width of 2/1/1 granny knots which were no wider than the 2/1/1 granny knots. The Mersilene knots were larger than the nylon ones. CONCLUSION The use of 2/1/1 reef knots is recommended for corneal suturing.
منابع مشابه
Parallel alternating sliding knots are effective for ligation of mesenteric arteries during resection and anastomosis of the equine jejunum
BACKGROUND In literature only one article describes and compares methods of achieving hemostasis in equine mesenteric arteries during jejunal resection and anastomosis, and most textbooks favor ligating-dividing mechanical devices. The latter method cannot always be used, not least because the devices are expensive and in some cases even contra-indicated. Various types of knots, including slidi...
متن کاملString Theory: an Examination of the Properties of “high Strength” Suture Materials
The evolution of arthroscopic shoulder surgery has lead to advanced developments in instrumentation and equipment. Pivotal to successful surgery are the high strength sutures. With all claiming high strength, we aimed to assess biophysical properties of each material via light microscopy, scanning electron microscope and mechanical testing. Peak load and stiffness were assessed using a knot fre...
متن کاملAn in vivo comparison of barbed suture devices and conventional monofilament sutures for cosmetic skin closure: biomechanical wound strength and histology.
BACKGROUND Very little biomechanical or histological data exist in the peer-reviewed literature comparing absorbable monofilament sutures to commercially-available knotless, absorbable barbed suture devices for cosmetic closure of skin incisions. OBJECTIVES The authors compare two commercially-available knotless, barbed suture devices against a conventional monofilament suture in a porcine mo...
متن کاملUse of barbed suture in robot-assisted mitral valvuloplasty.
Robot-assisted annuloplasty using a mitral band has a major issue: suturing is time consuming because knot tying is performed mechanically under endoscopic view. We suture the mitral band to the native valve by running sutures using the V-Loc barbed suture nonabsorbable wound closure device (Covidien, Mansfield, MA) with 3-0 monofilament. This technique allows rapid suturing of the band to the ...
متن کاملSystematic Evaluation of Effect of Myrtle and Fenugreek on Initial Inflammatory Response of Lingual Muscles to Different Types of Suturing Material in Diabetic Rats
Introduction: Several studies have been conducted to examine the effect of suture material on the skin during healing of the wound while a few articles reviewed the musculoskeletal response. In this study, the effects of the two plants, myrtle and fenugreek, on the primary inflammatory response of the tongue muscles to the types of suture in diabetic rats are examined. Materials and Methods: F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 80 2 شماره
صفحات -
تاریخ انتشار 1996