ON STANDARD CALIBRATION OF ISQ TRANSDUCER PEGS. Prerequisites for accurate and comparable RFA measurements
نویسنده
چکیده
The resonance frequency analysis (RFA) technique is widely used for stability assessments of dental implants. The technique makes use of a transducer peg, which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the peg. The underlying RF in Hz is then translated to an Implant Stability Quotient (ISQ) on a scale of 100 ISQ units. It is of importance that different implant types with the same stability show the same ISQ value. One potential problem with the first RFA technique is that the different pegs for different implant types have not been properly calibrated. Research has shown that ISQ values correlate well with bone density at the implant site, i.e. interface stiffness and clamping ability of the surrounding bone. The present paper presents a novel technique for standard calibration of the new generation of ISQ transducer –the MulTipegTM.
منابع مشابه
Resonance frequency analysis-reliability in third generation instruments: Osstell mentor®
UNLABELLED Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). OBJECTIVE Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the ...
متن کاملRESONANCE FREQUENCY ANALYSIS FOR IMPLANT STABILITY MEASUREMENTS. A review
The resonance frequency analysis (RFA) technique for implant stability measurements was developed by Meredith and coworkers more than 20 years ago. RFA makes use of a transducer (peg), which is attached to the implant and excited over a range of frequencies by electro-magnetic waves to measure the resonance frequency (RF) of the transducer. The underlying RF measurements in Hz are translated to...
متن کاملAssessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study
UNLABELLED Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. OBJECTIVE Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) ...
متن کاملDetermination of primary stability: a comparison of the surgeon's perception and objective measurements.
PURPOSE To evaluate the difference between the dental surgeon's perception of implant stability and the actual insertion torque and actual values obtained through resonance frequency analysis (RFA) during implant insertion surgery. MATERIALS AND METHODS One hundred fifty-two patients who needed one or more dental implants were selected. A total of 514 Xive implants was inserted. For all 514 i...
متن کاملComparative analysis of 2 resonance frequency measurement devices: Osstell Mentor and Osstell ISQ.
OBJECTIVE Comparing reliability of Osstell Mentor and Osstell ISQ in implant stability measurement, and assessing whether their measurements are comparable. MATERIALS AND METHOD Implant stability was measured with both devices on 58 implants in 15 patients. Six measurements were completed with each device with 2 different transducers (3 measurements with each transducer), that is, 12 measurem...