Reconstruction of cone-beam projections from Compton scattered data

نویسنده

  • Lucas C. Parra
چکیده

The problem of reconstructing a 3D source distribution from Compton scattered data can be separated into two tasks. First, the angular distribution of line projections at different observation points within the detector volume are reconstructed. Then, reconstruction techniques are applied to the resulting cone-beam projections to synthesize the 3D source distribution. This paper describes an analytic solution for the first, yet unsolved, task. Building on the convolution theorem in spherical coordinates, a back-projection and inverse filtering technique in terms of spherical harmonics is formulated. The rotation invariance of the point response of the back-projection in spherical coordinates is proved; and the corresponding inverse filter function is derived. The resulting filtered back-projection algorithm then consists of a summation over all detected events of fixed and known event response functions. Measurement errors, which for Compton scatter detectors are typically different for each detected event, can easily be accounted for in the proposed algorithm. The computational cost of the algorithm is O(NT 2), where N is the number of detected events and =T is the desired angular resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a Physical Based Approach of Scattered Radiation Correction in Cone Beam CT for Non-Destructive Testing Applications

Cone Beam Computerized Tomography (CBCT) enables threedimensional imaging with isotropic resolution. X-ray scatter management is a challenging task for quantitative CBCT imaging : scattered radiation level is significantly high on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation are cupping artifacts, streaks, and quantification inaccuracies. At...

متن کامل

Application of spherical harmonics to image reconstruction for the Compton camera.

The Compton camera can collect SPECT data with high efficiency due to electronic collimation. The data acquired from a Compton camera are projections of source activity along cones and are approximated in this paper by cone-surface integrals. This paper proposes the use of an orthogonal spherical expansion to convert the cone-surface integrals into plane integrals. The conversion technique is e...

متن کامل

A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography

A filtered backprojection reconstruction algorithm was developed for cardiac single photon emission computed tomography with cone-beam geometry. The algorithm reconstructs cone-beam projections collected from ;short scan' acquisitions of a detector traversing a noncircular planar orbit. Since the algorithm does not correct for photon attenuation, it is designed to reconstruct data collected ove...

متن کامل

A Generalized Model for 3D Compton Scatter in Single Photon Emission Computed Tomography Using Slice-by-Slice Blurring and Scatter Projection Rebinning

The modeling of 3D Compton scatter in SPECT is complicated by the use of a variety of collimator geometry. To date, effective and efficient modeling of 3D Compton scatter in parallel-beam SPECT has been made possible by Frey and Tsui [1], Zeng et al [2], and Bai et al [3]. For fan-beam and cone-beam SPECT, the model in [3] can effectively model first order 3D Compton scatter. But for varying-fo...

متن کامل

An error-reduction-based algorithm for cone-beam computed tomography.

Image reconstruction from cone-beam projections collected along a single circular source trajectory is commonly done using the Feldkamp algorithm, which performs well only with a small cone angle. In this report, we propose an error-reduction-based algorithm to increase the cone angle by several folds to achieve satisfactory image quality at the same radiation dose. In our scheme, we first reco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000