Case Report A 64-year-old man was admitted to our institution on November 7, 2011, complaining of chest pain upon exertion for the previous year. Prior history: hypertension for more than 10 years, highest blood pressure 215/115 mmHg, 30-year history of smoking, 10 cigarettes per day. ECG on admission showed: increased II, III, AVF leads, small electrocardiogram (EKG)’s Q waves (Q), EKG’s ST segment (ST) depression 0.05 mv, T wave inversion. Admission diagnosis: 1) coronary old inferior myocardial infarction, unstable angina, New York Heart Association (NYHA) chronic heart failure (CHF) class II. 2) Hypertension class III. Cardiac catheterization, via the right radial artery: Left Main no stenosis, middle Left Anterior Descending (LAD) is 50% and distal 60% stenosis. Proximal Left Circumflex (LCx) showed 50-60 % stenosis, middle diffuse stenosis 90%. Two collateral circulation pathways were also observed: LAD to septal branch to Right Coronary Artery (RCA) with formation of limited myocardial collateral circulation; however, the LCx to left atrial branch to RCA epicardial collateral circulation showed good collateral blood supply (Figure 1 A). Selective right coronary angiography did not find the opening for the RCA, non-selective angiography suggested that the opening of the RCA could be totally occluded or the origin was abnormal (B). Because the patient refused coronary artery bypass surgery, it was decided to use a retrograde guidewire trapping technique using a “Memory-Snare” device by Shanghai Shape Memory Alloy Co. Ltd., China. A 7F EBU 3.75 guide catheter was placed via the right femoral artery, to the left coronary ostium. Super-selective angiography using a “Finecross” micro-catheter was performed. The septal branch did not show good collateral circulation to the distal right coronary (C). The Finecross was then sent into the circumflex artery to the left atrial branch over a Fielder Fc guidewire. Tip injection showed there was good collateral flow to the RCA (D, E). The Finecross was exchanged for an Abbot Vascular Pilot 150 catheter and passed by the retrograde route through the proximal right coronary occlusion, following an anomalous route into the ascending aorta, where it could be captured by the Memory-Snare device. Subsequently, a JR 4.0 guiding catheter was placed via the right radial artery and sent to the right coronary sinus; the angiography showed anomalous origin of right coronary openings (F). The same JR 4.0 guiding catheter was then used to deploy the Memory Snare device. The Pilot 150 guidewire was then connected to an extension wire. The Memory Snare device was used to capture the retrograde Pilot 150 into the JR 4.0 guiding catheter (Figure 2, Panel G), and pull it out of the body though the radial artery (Figure 2, Panel H). Antegrade along the Pilot 150 guidewire, a PTCA 2.0 × 20 mm balloon catheter was inserted and used to enlarge the stenosis of the RCA (Figure 2, Panel I); angiography identified the abnormal RCA opening on the left coronary sinus. Also visible was the stenosis throughout the length of the RCA (Figure 2, Panel J). Implantation of Partner rapamycin-eluting stents in the distal, middle and proximal right coronary, respectively (Figure 2, Panel K); postoperative angiography showed good RCA imaging with Thrombolysis In Myocardial Infarction (TIMI) 3 flow grade, without residual stenosis in the stents (Figure 2, Panel L).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Retrograde Approach to Coronary Ostial Stenosis after a Bentall Procedure in a Patient with Behçet's Disease

We describe a case of chronic total occlusion of the right coronary artery ostium 5 months after a repeated Bentall procedure in a patient with Behçet's disease. In this patient, an antegrade approach to delivering the guidewire during percutaneous coronary intervention was not successful. Coronary angiography revealed the existence of collateral blood supply from the left coronary artery. Usin...

متن کامل

Application of a snare technique in retrograde chronic total occlusion percutaneous coronary intervention – a step by step practical approach and an observational study

Percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) has recently become popular among interventional cardiologists. CTO originating from the ostium has been one of the most difficult CTO lesions to treat with PCI for a number of reasons. Our aim was to illustrate a specific technique during retrograde CTO PCI referred to as the "snare technique."We retrospectively examine...

متن کامل

A case with successful retrograde stent delivery via AC branch for tortuous right coronary artery.

The retrograde approach is a novel technique of percutaneous coronary intervention for chronic total occlusion. This technique has improved the success rate of guidewire passage through the occlusion. In the retrograde approach, a microcatheter and balloon are delivered through a retrograde channel. However, it is difficult for a stent to pass through collateral arteries. We report a case of co...

متن کامل

Reverse Controlled Antegrade and Retrograde Subintimal Tracking in Chronic Total Occlusion of Right Coronary Artery

Passage failure of guidewire is still remained most common reason for percutaneous coronary intervention (PCI) failure in chronic total occlusion (CTO). Intravascular ultrasound study (IVUS) and cardiac CT angiography can help identify features that most influence current success rates of PCI. We report our experience using the reverse controlled antegrade and retrograde subintimal tracking tec...

متن کامل

Aortocoronary dissection complicating percutaneous angioplasty.

A 56-year-old man was admitted to our hospital for elective coronary angioplasty of a chronic total occlusion (CTO) of the right coronary artery (RCA). After insertion of a right femoral sheath, the RCA was engaged with a 6 French Amplatz AL-2 (Cordis, Miami, Fl, USA) guiding catheter. Recanalization was begun using a 0.014-inch Miracle 3 guidewire (Asahi Intecc, Japan). At this stage, an ostia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de cardiologia

دوره 100 6  شماره 

صفحات  -

تاریخ انتشار 2013