Acute toxicity and early cosmetic outcome in patients treated with multilumen balloon brachytherapy with skin spacing ≤ 7.0 millimeters

نویسندگان

  • Kiwhoon Lee
  • Amy Quillo
  • Dustin Dillon
  • Keith Sowards
  • Allison Hatmaker
  • Anthony Dragun
چکیده

PURPOSE To review institutional experience treating patients who underwent breast conserving surgery and adjuvant accelerated partial breast irradiation with multilumen balloon brachytherapy (MLB) with close skin spacing (≤7 mm). MATERIAL AND METHODS Since July 2009, 26 patients with skin spacing ≤ 7.0 mm were treated with breast-conserving therapy and adjuvant MLB brachytherapy. Patients were treated with either the Contura or MammoSite ML catheter to a total dose of 34 Gy in 10 fractions. Patients were assessed for acute toxicity at the completion of treatment and 1-month post treatment. Cosmesis and late toxicity were assessed at three-month intervals thereafter. RESULTS The median age of the patients was 56 years and median follow-up was 9 months. Sixteen patients had skin spacing of 5.0-7.0 mm, 10 with < 5.0 mm (median 5.8). The median percentage of the target (PTV_EVAL) receiving ≥ 95% of the prescription dose was 95.6%. The median volume of PTV_EVAL receiving ≥ 200% of the prescription dose was 6.1 cc. The maximum skin dose was 118.2% (median). The most commonly observed acute toxicity was grade 1-2 dermatitis (65.4%). The rate of post-treatment seroma and infection was 38.5% and 3.8%, respectively. Excellent/good cosmetic outcomes seen at the time of last follow-up was 92.3%. CONCLUSIONS MLB brachytherapy is safe and feasible in patients with close skin spacing, with acute toxicity and early cosmesis similar to other published series. These devices may broaden the application of balloon brachytherapy in patients previously excluded from this treatment based on anatomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical outcomes, toxicity, and cosmesis in breast cancer patients with close skin spacing treated with accelerated partial breast irradiation (APBI) using multi-lumen/catheter applicators

PURPOSE Accelerated partial breast irradiation (APBI) using a single-lumen device is associated with better cosmetic outcomes if the spacing between the applicator and skin is > 7 mm. However, there are no reports addressing the late toxicity and clinical outcomes in patients treated with single-entry multi-lumen/catheter applicators who had close skin spacing (7 mm or less). We undertook this ...

متن کامل

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

Multi-institutional experience using the MammoSite radiation therapy system in the treatment of early-stage breast cancer: 2-year results.

PURPOSE To present a retrospective multi-institutional experience of patients treated with the MammoSite radiation therapy system (RTS). METHODS AND MATERIALS Nine institutions participated in a pooled analysis of data evaluating the clinical experience of the MammoSite RTS for delivering accelerated partial breast irradiation. Between 2000 and 2004, 483 patients were treated with the MammoSi...

متن کامل

Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high‐dose‐rate brachytherapy for breast cancer

The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high-dose-rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7 cm for A; only rib spacing was ≤ 0.7 cm for B. Thirty-five rotation scenari...

متن کامل

Analysis of treatment efficacy, cosmesis, and toxicity using the MammoSite breast brachytherapy catheter to deliver accelerated partial-breast irradiation: the william beaumont hospital experience.

PURPOSE To review our institution's experience of treating patients with the MammoSite (Cytyc Corp., Marlborough, MA) breast brachytherapy catheter to deliver accelerated partial-breast irradiation (APBI), for determining short-term treatment efficacy, cosmesis, and toxicity. METHODS AND MATERIALS From January 2000 to April 2006, 80 patients treated with breast-conserving therapy (BCT) receiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012