Mass isotopomer distribution analysis at eight years: theoretical, analytic, and experimental considerations.
نویسندگان
چکیده
Mass isotopomer distribution analysis (MIDA) is a technique for measuring the synthesis of biological polymers. First developed approximately eight years ago, MIDA has been used for measuring the synthesis of lipids, carbohydrates, and proteins. The technique involves quantifying by mass spectrometry the relative abundances of molecular species of a polymer differing only in mass (mass isotopomers), after introduction of a stable isotope-labeled precursor. The mass isotopomer pattern, or distribution, is analyzed according to a combinatorial probability model by comparing measured abundances to theoretical distributions predicted from the binomial or multinomial expansion. For combinatorial probabilities to be applicable, a labeled precursor must therefore combine with itself in the form of two or more repeating subunits. MIDA allows dilution in the monomeric (precursor) and polymeric (product) pools to be determined. Kinetic parameters can then be calculated (e.g., replacement rate of the polymer, fractional contribution from the endogenous biosynthetic pathway, absolute rate of biosynthesis). Several issues remain unresolved, however. We consider here the impact of various deviations from the simple combinatorial probability model of biosynthesis and describe the analytic requirements for successful use of MIDA. A formal mathematical algorithm is presented for generating tables and equations ( ), on the basis of which effects of various confounding factors are simulated. These include variations in natural isotope abundances, isotopic disequilibrium in the precursor pool, more than one biosynthetic precursor pool, incorrect values for number of subunits present, and concurrent measurement of turnover from exogenously labeled polymers. We describe a strategy for testing whether isotopic inhomogeneity (e.g., an isotopic gradient or separate biosynthetic sites) is present in the precursor pool by comparing higher-mass (multiply labeled) to lower-mass (single- and double-labeled) isotopomer patterns. Also, an algebraic correction is presented for calculating fractional synthesis when an incomplete ion spectrum is monitored, and an approach for assessing the sensitivity of biosynthetic parameters to measurement error is described. The different calculation algorithms published for MIDA are compared; all share a common model, use overlapping solutions to computational problems, and generate identical results. Finally, we discuss the major practical issue for using MIDA at present: quantitative inaccuracy of instruments. The nature and causes of analytic inaccuracy, strategies for evaluating instrument performance, and guidelines for optimizing accuracy and reducing impact on biosynthetic parameters are suggested. Adherence to certain analytic guidelines, particularly attention to concentration effects on mass isotopomer ratios and maximizing enrichments in the isotopomers of interest, reduces error. Improving instrument accuracy for quantification of isotopomer ratios is perhaps the highest priority for this field. In conclusion, MIDA remains the "equation for biosynthesis," but attention to potentially confounding factors and analytic performance is required for optimal application.
منابع مشابه
AENDO June 39/6
Hellerstein, Marc K., and Richard A. Neese. Mass isotopomer distribution analysis at eight years: theoretical, analytic, and experimental considerations. Am. J. Physiol. 276 (Endocrinol. Metab. 39): E1146–E1170, 1999.—Mass isotopomer distribution analysis (MIDA) is a technique for measuring the synthesis of biological polymers. First developed approximately eight years ago, MIDA has been used f...
متن کاملMeasuring protein synthesis by mass isotopomer distribution analysis (MIDA).
The measurement of protein kinetics by isotopic techniques has been hindered by the long-standing difficulty of accurately measuring the isotope content of the biosynthetic precursor pool (aminoacyl-tRNA in tissues). Mass isotopomer distribution analysis (MIDA) is a stable isotope-mass spectrometric (MS) technique for measuring biosynthetic precursor enrichments from measurements on a polymeric...
متن کاملIsotopomer distribution computation from tandem mass spectrometric data with overlapping fragment spectra
We present a method for determination of the isotopomer distributions of metabolites from the data generated by a tandem mass spectrometer. The method is an improvement over existing method as it is able to deal with overlapping fragments in the spectra. Our experiments indicate that the new method surpasses its predecessors in separating isotopomers from each other. When using the daughter ion...
متن کاملGC-MS analysis of amino acids rapidly provides rich information for isotopomer balancing.
Gas chromatography-mass spectrometry (GC-MS) is a rapid method that provides rich information on isotopomer distributions for metabolic flux analysis. First, we established a fast and reliable experimental protocol for GC-MS analysis of amino acids from total biomass hydrolyzates, and common experimental pitfalls are discussed. Second, a suitable interface for the use of mass isotopomer data is...
متن کاملStudies of glycogen synthesis and the Krebs cycle by mass isotopomer analysis with [U-13C]glucose in rats.
Starved rats were infused intragastrically via indwelling duodenal cannulae with glucose at a rate of 30 mg/min/kg. The infusate contained [U-13C]glucose at an enrichment of 32 or 17%. At the end of the infusion, after 160 min, glucose and lactate were isolated from arterial and portal blood and from liver, and liver glycogen was isolated and hydrolyzed to glucose. The enrichment in glucose and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Endocrinology and metabolism
دوره 276 6 شماره
صفحات -
تاریخ انتشار 1999