Radiation Doses to Patients in Interventional Coronary Procedures-Estimation of Updated National Reference Levels by Dose Audit.
نویسندگان
چکیده
The objective of this study was to estimate the French national updated reference levels (RLs) for coronary angiography (CA) and percutaneous coronary intervention (PCI) by a dose audit from a large data set of unselected procedures and in standard-sized patients. Kerma-area product (PKA), air kerma at interventional point (Ka,r), fluoroscopy time (FT), and the number of registered frames (NFs) and runs (NRs) were collected from 51 229 CAs and 42 222 PCIs performed over a 12-month period at 61 French hospitals. RLs estimated by the 75th percentile in CAs and PCIs performed in unselected patients were 36 and 78 Gy.cm² for PKA, 498 and 1285 mGy for Ka,r, 6 and 15 min for FT, and 566 and 960 for NF, respectively. These values were consistent with the RLs calculated in standard-sized patients. The large difference in dose between sexes leads us to propose specific RLs in males and females. The results suggest a trend for a time-course reduction in RLs for interventional coronary procedures.
منابع مشابه
Patient dose values during interventional cardiology examinations in Yazd hospital, Iran
Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...
متن کاملThe need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography
Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...
متن کاملAssessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran
Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...
متن کاملAssessment of Maximum Entrance Skin Dose of Patients Undergoing Cardiac Interventional Procedures and Its Correlation with Other Dosimetric Parameters
Introduction: In recent years, the number of complex coronary angiography (CA) is increasing rapidly. These procedures have a significant contribution to medical exposure to the general population. Exposure of patients to high doses of x-rays could cause deterministic effects on the skin. Therefore, the assessment of radiation doses of patients is of great importance. ...
متن کاملEstimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria
Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 175 1 شماره
صفحات -
تاریخ انتشار 2017