Anti-Slide
نویسندگان
چکیده
The anti-slide packing is a packing of a number of three dimensional pieces of same size into a larger box such that none of them can slide in any direction. In this paper, we consider the problem of how to find a sparsest anti-slide packing. We give an IP formulation of this problem, and obtain the solutions for some small cases by using an IP solver. In addition, we give the upper and lower bounds on the ratio of the volume occupied by the pieces when the size of a box approaches infinity. For the case of piece size 2 × 2 × 1, we show that a sparsest anti-slide packing occupies at least 28.8% and at most 66.7% of the total volume.
منابع مشابه
A modified rapid slide test for anti-streptolysin O.
This paper describes the modification of a commercially available rapid slide screening test(1) for anti-streptolysin O to give quantitative results. The modified technique is compared with the long-established haemolytic technique of Rantz and Randall (1945). The quantitative results for both techniques are shown to be comparable. The modified slide test offers the advantage of saving time and...
متن کاملPerformance Evaluation of Nano-Lubricants at Thrust Slide-Bearing of Scroll Compressors
This paper presents the friction and anti-wear characteristics of nano-oil with a mixture of refrigerant oil and carbon nano-particles in the thrust slide-bearing of scroll compressors. Frictional loss in the thrust slide-bearing occupies a large part of total mechanical loss in scroll compressors. The characteristics of friction and anti-wear using nano-oil is evaluated using a thrust bearing ...
متن کاملDevelopment of slide micro-agglutination system for the rapid diagnosis of Salmonella infection in the chicken
The cultural method to identify avian Salmonella infections is laborious and expensive, thus a rapid, sensitive and cost-effective method for the diagnosis of salmonellosis is anticipated. S. pullorum was isolated and a stained Salmonella somatic antigen was prepared. The protein concentration of stained antigen was measured and adjusted to 3000 ng/μl. Preservative was used to increase its shel...
متن کاملCompatibility testing without a centrifuge: the slide Polybrene method.
BACKGROUND A simple and rapid slide Polybrene method (SP) for pretransfusion compatibility testing is described. SP is particularly suitable for use in developing countries where, due to limited resources, centrifuges and biologic reagents may not be readily available. STUDY DESIGN AND METHODS The original manual Polybrene method (MP) was modified for use on glass microscope slides, eliminati...
متن کاملDetection of platelet-directed immunoglobin G in sera using the peroxidase-anti-peroxidase (PAP) slide technique.
An immunohistochemical procedure for the detection of immunoglobulin G adherent to platelets is described. The peroxidase anti-peroxidase method is used to detect antibody activity directed against platelets from normal donors in the sera from 305 individuals. These subjects were divided into three groups: group 1, patients referred for tissue typing; group 2, healthy normal females; group 3, h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JIP
دوره 23 شماره
صفحات -
تاریخ انتشار 2015