Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy.
نویسندگان
چکیده
OBJECTIVES Persisting air leakage after pulmonary resection remains a significant problem. The aim of the study was to evaluate the incidence of air leakage after standard lobectomy and test the efficacy and safety of TachoComb (TC). METHODS A total of 189 patients undergoing lobectomy were enrolled in a multi-centre, open, randomised, and prospective study to test the efficacy and safety of TachoComb (TC) for air leakage treatment. Air leakage was assessed by water submersion test, and scored as grades 0 if no, 1 if countable, 2 if a stream of and 3 if coalescent bubbles have been observed. Any sites with grade 3 air leakage received further stapling or limited suturing until grade 0, 1 or 2 was obtained. Treatment of air leakage was done with TC or suturing according to randomisation. Air leakage was assessed by further submersion tests. Postoperative air leakage was assessed using the Pleur-Evac system. RESULTS Overall incidence of air leakage 48+/-6 h after surgery was 34% for TC and 37% for standard treatment (P=0.76). The reduction of intra-operative air leak intensity in the subgroup with grades 1-2 was significantly higher for the TC group (P=0.015). Postoperative air leakage intensity in the subgroup with air leakage grades 1-2 was lower for TC than standard treatment (P=0.047). The mean duration of postoperative air leakage in the subgroup with grades 1-2 was shorter for the TC group than for standard treatment, i.e. 1.9+/-1.4 vs. 2.7+/-2.2 days (P=0.015). CONCLUSIONS TC could be proven as well-tolerated and safe. In the subgroup of patients with established air leakage, TC showed superior potential in reduction of intra-operative air leakage as well as in reduction of intensity and duration of postoperative air leakage.
منابع مشابه
The sealing effect of fibrin glue against alveolar air leakage evaluated up to 48 h; comparison between different methods of application.
OBJECTIVE There is little experimental evidence to show how much positive airway pressure fibrin sealants can actually withstand, and in particular, how this effect changes over time. In the present study, we experimentally evaluated the sealing effect of fibrin glue against alveolar air leakage up to 48 h after application. METHODS Beagles were used (n = 48). Under thoracotomy, approximately...
متن کاملThe effects of sheet-type absorbable topical collagen hemostat used to prevent pulmonary fistula after lung surgery.
BACKGROUND Numerous reports have been published on the application of fibrin glues, biological adhesives used as sealants for air leaks after pulmonary resection; however, the use of blood products has been questioned from both safety and economic perspectives. Therefore we were prompted to attempt the use of Integran (method C), a sheet-type absorbable topical collagen hemostat that is neither...
متن کاملEfficacy and safety of TachoSil® versus standard treatment of air leakage after pulmonary lobectomy.
OBJECTIVES Alveolar air leakage remains a serious problem in lung surgery, being associated with increased postoperative morbidity, prolonged hospital stay and greater health-care costs. The aim of this study was to evaluate the sealing efficacy and safety of the surgical patch, TachoSil®, in lung surgery. METHODS Patients undergoing elective pulmonary lobectomy who had grade 1 or 2 air leaka...
متن کاملThe use of haemostatic agents in thyroid surgery: efficacy and further advantages. Collagen-Fibrinogen-Thrombin Patch (CFTP) versus Cellulose Gauze.
AIM To assess the efficacy of two widely used topical haemostatic agents: oxidised regenerated cellulose gauze and Collagen- Fibrinogen-Thrombin Patch in patients undergoing total thyroidectomy. MATERIAL OF STUDY This was a prospective, comparative, non-randomised study in which consecutive patients undergoing total thyroidectomy for benign disease received standard treatment with no haemosta...
متن کاملTachoSil use in abdominal surgery: a review
The success of any surgical procedure is based on adequate hemostasis. Many different biomaterial products can be used to achieve that aim. The products that can be used during surgery may be classified as topical hemostats, sealants, and adhesives. Hemostats can clot blood. Sealants can create sealing barriers. Adhesives bond tissue together. Collagen, gelatin, and cellulose are hemostat agent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2004