Quadricuspid aortic valve by using intraoperative transesophageal echocardiography

نویسندگان

  • Zhenghua Xiao
  • Wei Meng
  • Eryong Zhang
چکیده

Quadricuspid aortic valve is a rare congenital malformation of the aortic valve. Its diagnosis is often missed even with the use of transthoracic echocardiogram. Many of these patients progress to aortic incompetence later in life, hence requiring surgical intervention. In the case described in this report, a 61-year-old woman is presented with the features of congestive heart failure. The preoperative transthoracic echocardiogram disclosed a moderate to severe aortic valve insufficiency but failed to reveal the quadricuspid aortic value anomaly. This case underscores the important role of three-dimensional transesophageal echocardiography for the diagnosis of quadricuspid aortic valve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quadricuspid Aortic Valve: A Rare Intraoperative Diagnosis by Transesophageal Echocardiography

Quadricuspid aortic valve (QAV) is a rare congenital anomaly frequently associated with other anomalies particularly coronary anomalies. It may be detected on transthoracic or transesophageal echocardiography. We present here a case report of a 27-year-old male patient with a QAV, the valve being regurgitant and requiring aortic valve replacement. It has been reported as isolated case reports i...

متن کامل

Quadricuspid Aortic Valve Diagnosed by Transesophageal Echocardiography: A Case Report

Quadricuspid aortic valve (QAV) is an uncommon congenital anomaly which was an incidental finding during surgery or autopsy in the past. We present the case of a 44-year-old woman with moderately severe aortic regurgitation due to unequal cusp size QAV diagnosed via transesophageal echocardiography. Due to echocardiographic imaging improvement, the diagnosis of QAV is now easier and earlier tha...

متن کامل

A rare cause of severe aortic regurgitation: quadricuspid aortic valve.

Quadricuspid aortic valve (QAV) is a rare cause of valve failure. Often, it is an incidental finding at transesophageal echo (TEE), surgery or post-mortem examination. This anomaly is often associated with abnormally placed left coronary ostium that could be damaged during the operation. We report a case of QAV detected incidentally during perioperative TEE.

متن کامل

Quadricuspid aortic valve with D (Rho) antigen negativity: a novel case report

Here we report a rare case of a Chinese female patient presenting with aortic insufficiency due to a quadricuspid aortic valve and Rho negativity. The 64-year-old woman was referred with a 1-month history of dyspnea and cough (NYHA class II). A quadricuspid aortic valve was suspected, and grade 3 aortic regurgitation was identified by transthoracic echocardiography (TTE). After admission, the A...

متن کامل

Aortic regurgitation due to quadricuspid aortic valve--case report and literature review.

Quadricuspid aortic valve is a rare variant of aortic semilunar valve, often being an unexpected discovery during cardiac surgery. We present the case of a 59 years old patient, who was admitted for dyspnea on light exertion and palpitations. The transthoracic echocardiography revealed severe aortic valve regurgitation due to a quadricuspid aortic valve, the result being confirmed by the transe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2010