Tailored Surface Treatment of 3D Printed Porous Ti6Al4V by Microarc Oxidation for Enhanced Osseointegration via Optimized Bone In-Growth Patterns and Interlocked Bone/Implant Interface.
نویسندگان
چکیده
3D printed porous titanium (Ti) holds enormous potential for load-bearing orthopedic applications. Although the 3D printing technique has good control over the macro-sturctures of porous Ti, the surface properties that affect tissue response are beyond its control, adding the need for tailored surface treatment to improve its osseointegration capacity. Here, the one step microarc oxidation (MAO) process was applied to a 3D printed porous Ti6Al4V (Ti64) scaffold to endow the scaffold with a homogeneous layer of microporous TiO2 and significant amounts of amorphous calcium-phosphate. Following the treatment, the porous Ti64 scaffolds exhibited a drastically improved apatite forming ability, cyto-compatibility, and alkaline phosphatase activity. In vivo test in a rabbit model showed that the bone in-growth at the untreated scaffold was in a pattern of distance osteogenesis by which bone formed only at the periphery of the scaffold. In contrast, the bone in-growth at the MAO-treated scaffold exhibited a pattern of contact osteogenesis by which bone formed in situ on the entire surface of the scaffold. This pattern of bone in-growth significantly increased bone formation both in and around the scaffold possibly through enhancement of bone formation and disruption of bone remodeling. Moreover, the implant surface of the MAO-treated scaffold interlocked with the bone tissues through the fabricated microporous topographies to generate a stronger bone/implant interface. The increased osteoinetegration strength was further proven by a push out test. MAO exhibits a high efficiency in the enhancement of osteointegration of porous Ti64 via optimizing the patterns of bone in-growth and bone/implant interlocking. Therefore, post-treatment of 3D printed porous Ti64 with MAO technology might open up several possibilities for the development of bioactive customized implants in orthopedic applications.
منابع مشابه
3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface.
UNLABELLED For load-bearing orthopaedic applications, metal implants having an interconnected pore structure exhibit the potential to facilitate bone ingrowth and the possibility for reducing the stiffness mismatch between the implant and bone, thus eliminating stress-shielding effects. 3D printed solid and macro-porous Ti6Al4V implants were evaluated after six-months healing in adult sheep fem...
متن کاملOsseointegration of TI6Al4V dental implants modified by thermal oxidation in osteoporotic rabbits
BACKGROUND In this work, the effect of the heat treatment on Ti6Al4V implants and topical administration of growth hormone to address a better osseointegration in osteoporotic patients has been analysed. METHODS The osseointegration process of Ti6Al4V implants modified by oxidation treatment at 700 °C for 1 h and the influence of local administration of growth hormone (GH) in osteoporotic fem...
متن کاملImmobilization of chitosan film containing semaphorin 3A onto a microarc oxidized titanium implant surface via silane reaction to improve MG63 osteogenic differentiation
Improving osseointegration of extensively used titanium (Ti) implants still remains a main theme in implantology. Recently, grafting biomolecules onto a Ti surface has attracted more attention due to their direct participation in the osseointegration process around the implant. Semaphorin 3A (Sema3A) is a new proven osteoprotection molecule and is considered to be a promising therapeutic agent ...
متن کاملQuantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry
A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone ...
متن کاملOsseointegration of sintered porous-surfaced and plasma spray-coated implants: An animal model study of early postimplantation healing response and mechanical stability.
The osseointegration and long-term success of bone-interfacing implants are dependent on mechanical stability of the implant relative to host bone during the early healing period. The geometric design of an implant surface may play an important role in affecting early implant stabilization, possibly by influencing tissue healing dynamics. In this study, we compared the early tissue healing resp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ACS applied materials & interfaces
دوره 8 28 شماره
صفحات -
تاریخ انتشار 2016