Clinical measurement of serum amiodarone and desethylamiodarone by using solid-phase extraction followed by HPLC with a high-carbon reversed-phase column.

نویسندگان

  • M A Jandreski
  • W E Vanderslice
چکیده

We describe a rapid, simple HPLC method routinely used in our clinical laboratory for determining amiodarone and its metabolite desethylamiodarone. These compounds are released from serum proteins by pretreatment with an acidic solution and then extracted onto a C2 reversed-phase clean-up column. After elution from the extraction column, the compounds are separated and quantified by HPLC with a C18 reversed-phase column and spectrophotometric detection. The standard curves for the drug and metabolite are linear up to 20.0 mg/L, with a lower limit of detection of 0.16 mg/L. The CVs for intra-assay precision were 5.0% at 0.58 mg/L and 2.9% at 5.96 mg/L; for inter-assay precision, they were 9.6% at 0.52 mg/L and 6.1% at 2.09 mg/L. Lipemia, hemoglobin, and bilirubin up to 300 mg/L do not interfere with this assay. None of > 550 cardiac patients' samples tested contained a compound that interferes with this assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

The Combination Process for Preparative Separation and Purification of Paclitaxel and 10-Deacetylbaccatin III Using Diaion® Hp-20 Followed by Hydrophilic Interaction Based Solid Phase Extraction

There is no other naturally occurring defense agent against cancer that has a stronger effectthan paclitaxel, commonly known under the brand name of Taxol®. The major drawback for themore widespread use of paclitaxel and its precious precursor, 10-deacetylbaccatin III (10-DABIII), is that they require large-scale extraction from different parts of yew trees (Taxus species),cell cultures, taxane...

متن کامل

The Combination Process for Preparative Separation and Purification of Paclitaxel and 10-Deacetylbaccatin III Using Diaion® Hp-20 Followed by Hydrophilic Interaction Based Solid Phase Extraction

There is no other naturally occurring defense agent against cancer that has a stronger effectthan paclitaxel, commonly known under the brand name of Taxol®. The major drawback for themore widespread use of paclitaxel and its precious precursor, 10-deacetylbaccatin III (10-DABIII), is that they require large-scale extraction from different parts of yew trees (Taxus species),cell cultures, taxane...

متن کامل

Selective Extraction and Determination of Di(2-ethylhexyl) Phthalate in Aqueous Solution by HPLC Coupled with Molecularly Imprinted Solid-phase Extraction

Surface Molecularly Imprinted Polymer (SMIP) for selective adsorption of di(2-ethylhexyl) phthalate(DEHP) was prepared on the surface of silica gel which was modified by aminopropyltriethoxysilane and acryloyl chloride in a two-step method. The prepared SMIP was used to prepare Molecularly Imprinted Solid-Phase Extraction (MISPE) column for selective extraction of DEHP from aqueous solution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 1993