Procedures for the storage and digestion of natural waters for the determination of ®lterable reactive phosphorus, total ®lterable phosphorus and total phosphorus

نویسندگان

  • W. Maher
  • L. Woo
چکیده

An overview of the forms of phosphorus species likely to be encountered in natural waters and the implications for the measurement of ®lterable and total phosphorus is given. Procedures reported in the literature for the storage and digestion of water samples for ®lterable reactive phosphorus (FRP), total ®lterable phosphorus (TFP) and total phosphorus (TP) measurements are summarised and the advantages and limitations of methods discussed. Water samples for FRP and TFP measurements need to be ®ltered immediately on collection as exchange on and off particles may occur in the sample container. Slow freezing of ®ltered or turbid water samples in acid washed low density polyethylene bottles appears to be satisfactory for the long term storage (years) of a variety of water sample types. Storage of water samples at room temperature or refrigeration (1±58C) with a preservative is suitable only for short term storage (daysmonths). If water samples contain < 20 mg P/l, adsorption to containers may be signi®cant. Batch digestion of samples with alkaline or acid peroxodisulphate using autoclave or microwave heating offers the advantages of ease, simplicity and precision. Good recoveries of phosphorus from a range of phosphorus compounds containing P±O±P, C±O±P and C±P bonds expected in natural waters have been reported. If turbid samples are to be analysed, caution must be exercised to ensure that the carbon or suspended solids concentration does not exceed the capacity of the digestion procedure to oxidise the carbon present and release occluded phosphorus from particulate materials. Better recoveries of phosphorus from turbid water samples are achieved using microwave heating with closed vessels, probably because of the higher temperatures and pressures generated. The use of on-line heating (microwave, thermal induced) coupled with ̄ow injection analysis and using peroxodisulphate or an oxidising acid mixture should also allow the automation of TFP and TP measurements. Reliable procedures for the removal of unwanted particulate material prior to or after the digestion step need to be developed. # 1998 Published by Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sampling, sample treatment and quality assurance issues for the determination of phosphorus species in natural waters and soils.

Phosphorus is an important macronutrient and the accurate determination of phosphorus species in environmental matrices such as natural waters and soils is essential for understanding the biogeochemical cycling of the element, studying its role in ecosystem health and monitoring compliance with legislation. This paper provides a critical review of sample collection, storage and treatment proced...

متن کامل

Improvement of the wet-oxidation procedure for simultaneous determination of particulate organic nitrogen and phosphorus collected on filters

A new digestion technique is presented for simultaneous analysis of particulate organic nitrogen (PON) and particulate organic phosphorus (POP) collected on filters. This method is based on a standard persulfate digestion procedure at 120°C and adapted from a former method for the simultaneous determinat~on of total nitrogen and total phosphorus in natural waters. Comparisons 1~1th usual method...

متن کامل

Determination of dissolved reactive and dissolved total phosphorus in water extract of soils

The simplified acid peroxydisulphate digestion of soil water extract was evaluated for determination of total dis solved phosphorus by molybdenum-blue colorimetry in comparison with direct P-detection in water extract by the ICP-AES technique. The research was conducted on 79 agricultural soils with different agrochemical characteristics. The results of the colorimetric P detection in water ext...

متن کامل

Nutrient uptake rate and removal efficiency of Vetiveria zizanioides in contaminated waters

This research compares the performance of floating systems planted with Vetiveria zizanioides as a hydroponic approach for removing nutrients from two contaminated waters. For this purpose, two pilots with overall net volume of 60 litres were constructed and inoculated by secondary treated domestic wastewater (STDW) and irrigation water obtained from Minab reservoir (IWMR) in batch mode. Regard...

متن کامل

Nutrient uptake rate and removal efficiency of Vetiveria zizanioides in contaminated waters

This research compares the performance of floating systems planted with Vetiveria zizanioides as a hydroponic approach for removing nutrients from two contaminated waters. For this purpose, two pilots with overall net volume of 60 litres were constructed and inoculated by secondary treated domestic wastewater (STDW) and irrigation water obtained from Minab reservoir (IWMR) in batch mode. Regard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998