The purpose of the present investigation was to examine the mechanomyographic (MMG) responses to maximal eccentric isokinetic muscle actions. Eight adult male volunteers [age 22 +/- 2 (SD) yr] performed maximal eccentric muscle actions of the leg extensors at 60, 90, 120, and 180 degrees /s on a Cybex 6000 isokinetic dynamometer. MMG was detected by a piezoelectric crystal contact sensor placed over the vastus lateralis muscle. Test-retest intraclass correlations ranged from R = 0.88 to 0.97 for peak torque and from R = 0.97 to 0.98 for root mean square MMG amplitude values. There was no significant (P > 0.05) velocity-related change in eccentric peak torque; however, there was a significant (P < 0.05) increase in MMG between 60 [119 +/- 44 (SE) mV] and 180 degrees/s (302 +/- 128 mV). These findings indicated a velocity-related dissociation between MMG and peak torque for maximal eccentric isokinetic muscle actions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanomyographic and Electromyographic Responses to Isokinetic Muscle Actions

Mechanomyography (MMG) records and quantifies the low frequency lateral oscillations of active skeletal muscle fibers. It has been suggested that MMG is the mechanical counterpart of the motor unit electrical activity as measured by electromyography (EMG). Thus, simultaneous measurements of MMG and EMG may provide insight into the mechanical and electrical components of muscle function. MMG has...

متن کامل

Mechanomyographic responses during dynamic muscle actions

Surface mechanomyographic (MMG) signals have been detected during various types of dynamic muscle actions, including dynamic constant external resistance (DCER) muscle actions, concentric and eccentric isokinetic muscle actions, as well as incremental and constant power output cycle ergometry. Although the MMG amplitude and center frequency [mean power frequency (MPF) or median frequency] respo...

متن کامل

Mechanomyographic and electromyographic amplitude and frequency responses during fatiguing isokinetic muscle actions of the biceps brachii.

The purpose of this investigation was to examine the mechanomyographic (MMG) and electromyographic (EMG) amplitude and mean power frequency (MPF) patterns during fatiguing isokinetic muscle actions of the biceps brachii. Ten adults [three women (mean +/- SD age = 20 +/- 2 yrs) and seven men (mean +/- SD age = 23 +/- 3 yrs) ] volunteered to perform 50 consecutive maximal, concentric isokinetic m...

متن کامل

Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review

The purpose of this review is to examine the literature that has investigated mechanomyographic (MMG) amplitude and frequency responses during dynamic muscle actions. To date, the majority of MMG research has focused on isometric muscle actions. Recent studies, however, have examined the MMG time and/or frequency domain responses during various types of dynamic activities, including dynamic con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 1997