Design and Optimization of the Target in Electron Linear Accelerator

نویسندگان

  • Qiang Gao
  • Hao Zha
  • Huaibi Chen
  • Jiaru Shi
چکیده

The target in electron linear accelerator plays an important role in the production of photon. Different materials and thickness of target have influence on dose rate. For 6MeV electron beam, this study gives the thickness of target for several materials in which the dose rate can be higher and drain electron can be lower. Then a X-ray target had been designed for 6MeV electron linac by FLUKA simulations. It can deliver 1000 cGy/min at 1 meter in front of the target if providing 6 MeV electron beam with 100uA current, which can achieve high-dose rate radiotherapy. INTRODUCTION As known to all, with the efforts of many scientists, the X-ray has been widely used in medical therapy, agriculture and industry since 1895. Especially, it plays an important role in medical imaging and tumor cutting operation. Many simulations have been done to calculate the dose rate in medical accelerators [1]. The main three kinds of source to generate X-ray are laser plasma, synchrotron radiation and X-ray tube. Although laser plasma has a huge radiation intensity and synchrotron radiation can achieve a continuous wide frequency spectrum, X-ray tube is the most common generator because of its small size and cheap prize. Figure 1: Schematic representation of the simulated Clinac 2300EX treatment head [2]. Figure 1 shows a typical work principle of accelerator treatment head. Incident electrons shoot a target to generate X-ray through the bremsstrahlung effect, then the X-ray passes through the primary and second collimator to become a cone beam. Flattening filter is used as a radiation filter to affect the energy spectrum. For a certain kind of energy of incident electrons, a target with different thickness and materials has different conversion efficiencies. To find the best thickness and material of target with biggest conversion efficiency, a simulation for scanning parameters is needed. The Monte Carlo Method is the most popular tool in simulation to calculate the efficiency [3]. For 6 MeV electron beam, the conversion efficiency can be estimated by dose rate, which is an important parameter in radiation therapy. According to the report of ICRU, the accuracy of dose generated by irradiating tumor is within 5% [4], so the dose rate should be known accurately. This study shows that how the dose rate changes with materials and thickness. MODEL Considering that the simulation is calculated with FLUKA program, a simplification for the actual model is necessary. Single Material Target Model Figure 2: Single material target model. Figure 2 shows a single material target model established in FLUKA program. A circle plane surface electron source with a radius 2mm is used as the incident electron beam to hit on the centre of target. Then the photons generated by bremsstrahlung escape mainly from the other side of the target. A water phantom dose detector is placed at the distance of 1m from the source to give the dose rate result. The energy spectrum of electron source is generated by a 6 MeV accelerating tube which is designed by Qingxiu Jin in department of engineering physics, Tsinghua [5]. The target materials are respectively carbon, aluminium, copper, silver, tungsten, gold and lead. Each material is pure simple substance. Proceedings of IPAC2013, Shanghai, China THPWA016 08 Applications of Accelerators U01 Medical Applications ISBN 978-3-95450-122-9 3663 C op yr ig ht c ○ 20 13 by JA C oW — cc C re at iv e C om m on sA tt ri bu tio n 3. 0 (C C -B Y3. 0) Composite Material Target Figure 3: Composite material target model. Figure 3 shows a composite material target model established in FLUKA program. The target is designed with two layers, the former is made of high atomic number material and another is low Z material, which means the incident electron beam irradiates on the high Z target firstly. Other parameters have the same meaning as they do in single material target. RESULTS When the model is established, simulation can start. The number of particles in simulation is set to be 1000000 so that the relative error is lower than 5%. For each model, the detector records dose rate and leakage rate of electron energy. The electron energy leakage rate is the percentage of electron energy escaping from target. Results of Single Material Target Simulation For each material, the simulation scans the thickness of target to calculate the dose rate and the electron energy leakage rate. Figure 4: dose rate changing with thickness in different materials. Figure 5: electron energy leakage rate changing with thickness in different materials. Figure 4 and Figure 5 show the simulation result of single material target. It can be founded that there is a peak dose rate when the thickness is changing. Considering the condition that electron energy leakage rate should be lower than 0.05%, there is a thickness that can generate max dose rate. Combining the figure 3 and figure 4 it is easy to find the best thickness and dose rate. Table 1: best thickness for single material target Material Best thickness (cm) Dose rate (rad/min /100uA) Leakage rate (%) Carbon 1.8449 745.52 0.05 Aluminium 1.3780 914.78 0.05 Copper 0.4311 1111.90 0.05 Silver 0.3596 1167.10 0.05 Tungsten 0.2682 1078.10 0.05 Gold 0.3166 1003.10 0.05 lead 0.4828 1033.80 0.05 At the best thickness, the incident electron hitting on the target not only can generate a high dose rate but also can have a lower leakage rate. Results of Composite Material Target Simulation Composite material target has two parameters to be scanned. For each layer thickness of the material, FLUKA program can give the dose rate and electron energy leakage rate. In this work, combination of W and Al, W and Cu, W and Ag, W and Au (two similar materials) are studied. The reason why these materials is chose to be studied mainly is that they are common and can be got easily. Obviously, these materials are usually used in single material target. 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 200 400 600 80

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source

In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam coll...

متن کامل

Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

Localization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

متن کامل

معرفی پروژه طراحی و ساخت شتاب‌دهنده خطی الکترون پژوهشگاه دانش‌های بنیادی

One of the most commonly used types of accelerators is linear electron accelerator. There is a project is in progress in Institute for research in fundamental sciences (IPM) aiming to design and build such an accelerator. It is defined in such a way that all parts to be built in Iran as possibly as it can. In this paper, after a brief explanation of the components of an electron linear accelera...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Design, Simulation and Manufacture of a Multileaf Collimator to Confirm the Target Volumes in Intensity Modulated Radiation Therapy

Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013