Acute regional improvement of myocardial function after interventional transfemoral aortic valve replacement in aortic stenosis: A speckle tracking echocardiography study
نویسندگان
چکیده
BACKGROUND Transcatheter aortic valve implantation (TAVI) is a promising therapy for patients with severe aortic stenosis (AS) and high perioperative risk. New echocardiographic methods, including 2D Strain analysis, allow the more accurate measurement of left ventricular (LV) systolic function. The goal of this study was to describe the course of LV reverse remodelling immediately after TAVI in a broad spectrum of patients with symptomatic severe aortic valve stenosis. METHODS Thirty consecutive patients with symptomatic aortic valve stenosis and preserved LVEF underwent transfemoral aortic valve implantation. We performed echocardiography at baseline and one week after TAVI. Echocardiography included standard 2D and Doppler analysis of global systolic and diastolic function as well as 2D Strain measurements of longitudinal, radial and circumferential LV motion and Tissue Doppler echocardiography. RESULTS The baseline biplane LVEF was 57 ± 8.2%, the mean pressure gradient was 46.8 ± 17.2 mmHg and the mean valve area was 0.73 ± 0.27 cm(2). The average global longitudinal 2D strain of the left ventricle improved significantly from -15.1 (± 3.0) to -17.5 (± 2.4) % (p < .001). This was reflected mainly in improvement in the basal and medial segments while strain in the apex did not change significantly [-11.6 (± 5.2) % to -15.1 (± 5.5) % (p < .001), -13.9 (± 5.1) % to -16.8 (± 5.6) % (p < .001) and -19.2 (± 7.0) % to -20.0 (± 7.2) % (p = .481) respectively]. While circumferential strain [-18.1 (± 5.1) % vs. -18.9 (± 4.2) %, p = .607], radial strain [36.5 (± 13.7) % vs. 39.7 (± 17.2) %, p = .458] and the LVEF remained unchanged after one week [57.0 (± 8.2) % vs. 59.1 (± 8.1) %, p = .116]. CONCLUSION There is an acute improvement of myocardial longitudinal systolic function of the basal and medial segments measured by 2D Strain analysis immediately after TAVI. The radial, circumferential strain and LVEF does not change significantly in all patients acutely after TAVI. These data suggest that sensitive new echo methods can reliably detect early regional changes of myocardial function after TAVI before benefits in LVEF are detectable.
منابع مشابه
Sequential changes in myocardial function after valve replacement for aortic stenosis by speckle tracking echocardiography.
AIMS Regional myocardial function may change differently in different pathology. Speckle tracking echocardiography (STE) was applied to evaluate longitudinal, radial, and circumferential function in patients with aortic stenosis (AS) before, within 1 week, and 6 months after aortic valve replacement (AVR). METHODS AND RESULTS In 40 consecutive patients with severe AS, we acquired apical four-...
متن کاملProsthetic valve endocarditis: multiple complications in one patient.
strain measurement with 2-dimensional speckle-tracking echocardiography: definition of normal range. Impact of myocardial structure and function postinfarction on diastolic strain measurements: Implications for assessment of myocardial viability.gression of left ventricular diastolic dysfunction and risk of heart failure. Normal ranges of left ven-tricular strain: a meta-analysis. Inter-study r...
متن کاملTransfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis
INTRODUCTION Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. AIM We want to share our experience with transcatheter aor...
متن کاملShort-term effects of transcatheter aortic valve implantation.
BACKGROUND Aortic stenosis (AS) leads to remodeling of the left heart. Strain measurements enable the assessment of left atrial (LA) mechanics. The goal of this study was to evaluate the short-term effects of transcatheter aortic valve implantation (TAVI) on LA myocardial deformation as well as left ventricular (LV) diastolic function. METHODS Thirty-two patients with severe AS were prospecti...
متن کاملImpact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
BACKGROUND The aim of this study was to compare left ventricular (LV) remodeling using myocardial strain between patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) with and without prosthesis-patient mismatch (PPM). METHODS AND RESULTS In a retrospective study, speckle-tracking echocardiography was used to measure global longitudinal strain (G...
متن کامل