Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model

نویسندگان

  • Hennie Verburg
  • Laurens C. van de Ridder
  • Vincent W. J. Verhoeven
  • Peter Pilot
چکیده

BACKGROUND In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distribution and penetration depth in the total area underneath a tibia prosthesis. METHODS We defined the radiodensity ranges for trabecular tibia bone, polymethylmethacrylate (PMMA) cement and cement-penetrated trabecular bone and measured the percentages of cement penetration at various depths after cementing two tibia prostheses onto redundant femoral heads. One prosthesis was subsequently removed to examine the influence of the metal tibia prostheses on the quality of the CT images. The percentages of cement penetration in the CT slices were compared with percentages measured with photographs of the corresponding transversal slices. RESULTS Trabecular bone and cement-penetrated trabecular bone had no overlap in quantitative scale of radio-density. There was no significant difference in mean HU values when measuring with or without the tibia prosthesis. The percentages of measured cement-penetrated trabecular bone in the CT slices of the specimen were within the range of percentages that could be expected based on the measurements with the photographs (p = 0.04). CONCLUSIONS CT scan images provide valid results in measuring the penetration and distribution of cement into trabecular bone underneath the tibia component of a TKA. Since the proposed method does not turn metal elements into artefacts, it enables clinicians to assess the width and density of the cement mantle in vivo and to compare the results of different cementing methods in TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of tibial tray design on cement morphology in total knee arthroplasty

BACKGROUND Improvements to enforce primary fixation in cemented total knee arthroplasty have been suggested to be a key issue for long-term survival. In this context, it has been questioned whether specific implant design features influence bone cement morphology and hence primary interface strength. The purpose of this study was to investigate in vitro the influence of cement pockets on the ti...

متن کامل

Thermal Analysis of the Tibial Cement Interface with Modern Cementing Technique

BACKGROUND The major cause of cemented Total Knee Arthroplasty (TKA) failure is aseptic loosening of the tibial component necessitating revision surgery. Recently, multiple techniques have been described to maximize cement penetration depth and density in the proximal tibia during TKA to potentially avoid early loosening. While cement polymerisation is an exothermic reaction, minimal investigat...

متن کامل

Intrusion Characteristics of Three Bone Cements for Tibial Component of Total Knee Arthroplasty in a Cadaveric Bone Model.

The purpose of this study was to evaluate and compare the intrusion characteristics of Simplex-HV to Simplex-P and Palacos-R in cadaveric proximal tibial bone. Eighteen fresh-frozen cadaver proximal tibiae were examined with standard arthroplasty tibial cuts. Each tibia was randomly assigned to receive one of the three bone cements for use with finger packing technique. Sagittal sections were p...

متن کامل

Tibial component fixation with cement: full- versus surface-cementation techniques.

Despite excellent outcomes with cemented tibial components in total knee arthroplasty, it still is debated whether the tibial stem should be cemented and what the optimal tibial stem design should be. Proponents of full cementation of the tibial stem and component state that better short-term and long-term component fixation is achieved when full cementation is used. Advocates for surface cemen...

متن کامل

Cement penetration and stiffness of the cement-bone composite in the proximal tibia in a porcine model.

PURPOSE To assess the stiffness of the cement bone composite and the depth and uniformity of cement penetration into the surface of the tibial component during total knee reconstruction in a porcine model. METHODS The effectiveness of 3 protocols were compared: 2 commonly used cementing techniques-finger-packing of cement on the cut surface followed by impaction, and coating of the undersurfa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014