Visualization of lateral water transport pathways in soybean by a time of flight-secondary ion mass spectrometry cryo-system
نویسندگان
چکیده
Water movement between cells in a plant body is the basic phenomenon of plant solute transport; however, it has not been well documented due to limitations in observational techniques. This paper reports a visualization technique to observe water movement among plant cells in different tissues using a time of flight-secondary ion mass spectrometry (Tof-SIMS) cryo-system. The specific purpose of this study is to examine the route of water supply from xylem to stem tissues. The maximum resolution of Tof-SIMS imaging was 1.8 μm (defined as the three pixel step length), which allowed detection of water movement at the cellular level. Deuterium-labelled water was found in xylem vessels in the stem 2.5 min after the uptake of labelled water by soybean plants. The water moved from the xylem to the phloem, cambium, and cortex tissues within 30-60 min after water absorption. Deuterium ion counts in the phloem complex were slightly higher than those in the cortex and cambium tissue seen in enlarged images of stem cell tissue during high transpiration. However, deuterium ion counts in the phloem were lower than those in the cambium at night with no evaporative demand. These results indicate that the stem tissues do not receive water directly from the xylem, but rather from the phloem, during high evaporative demand. In contrast, xylem water would be directly supplied to the growing sink during the night without evaporative demand.
منابع مشابه
Visualizing mass transport in desorption electrospray ionization using time-of-flight secondary ion mass spectrometry.
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to determine the effect of ambient probe incidence angle on the amount and direction of analyte molecules transported from the sample surface for desorption electrospray ionization (DESI). Incidence angle was critical to both the lateral dispersion and vertical take-off angles of analyte molecules desorbed from the surface; as t...
متن کاملATP-Mediated Compositional Change in Peripheral Myelin Membranes: A Comparative Raman Spectroscopy and Time-Of-Flight Secondary Ion Mass Spectrometry Study
In the present paper we addressed a mechanism of the myelin reorganization initiated by extracellular ATP and adenosine in sciatic nerves of the frog Rana temporaria. In combination with Raman microspectroscopy, allowing noninvasive live-cell measurements, we employed time-of-flight secondary ion mass spectrometry (TOF-SIMS) to follow the underlying changes in chemical composition of myelin mem...
متن کاملDetection of ZrO2 Nanoparticles in Lung Tissue Sections by Time-of-Flight Secondary Ion Mass Spectrometry and Ion Beam Microscopy
The increasing use of nanoparticles (NP) in commercial products requires elaborated techniques to detect NP in the tissue of exposed organisms. However, due to the low amount of material, the detection and exact localization of NP within tissue sections is demanding. In this respect, Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and Ion Beam Microscopy (IBM) are promising techniques...
متن کاملCorrelative mass spectrometry imaging, applying time‐of‐flight secondary ion mass spectrometry and atmospheric pressure matrix‐assisted laser desorption/ionization to a single tissue section
RATIONALE Mass spectrometry imaging (MSI) is a powerful tool for mapping the surface of a sample. Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) offer complementary capabilities. Here, we present a workflow to apply both techniques to a single tissue section and combine the resulting data for the example ...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کامل