Energy cost of walking in transfemoral amputees: Comparison between Marlo Anatomical Socket and Ischial Containment Socket.
نویسندگان
چکیده
OBJECTIVE To compare energy cost of walking (ECW) and prosthesis-related perceived mobility with the Marlo Anatomical Socket (MAS(®)) and the Ischial Containment (IC) Socket. METHOD Transfemoral (TF) amputees were enrolled in the study. ECW tests were conducted inside, in a hallway with a regular floor surface. Subjects had to walk back and forth on a 61m linear course at their own self-selected speed. Metabolic and heart rate data were collected during the walking test using a portable gas analyzer. All measurements were made at steady state (SS). The tests were performed first using the IC socket and then after 30 days of MAS(®) use; the last test was carried out after 60 days of MAS(®) use. The amputees were also administered the Prosthetic Evaluation Questionnaire Mobility Section (PEQ MS) at the first and the last test to assess perceived potential for mobility using the prosthesis. RESULTS Seven long-term prosthesis users were analyzed. Their mean age was 33.9±9.3 years; all were employed, active, and used IC sockets. At the third walking test, the ECW with the MAS(®) was significantly lower than that with the IC socket (p=.016). PEQ MS data also improved significantly at the last evaluation (p<.018). CONCLUSION Results suggest that using the MAS(®), lowering the ECW and improving PEQ MS, could be a valid prosthesis design for active TF amputees compared to their usual IC socket.
منابع مشابه
Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
A system for measuring the stump-socket interface pressure was designed and built using a strain gauged type load cell. The system was utilized to study the pressure distribution in the quadrilateral and ischial containment type sockets. Two volunteer trans-femoral amputees fitted with both types of socket participated in the experiments. Pressures were measured while the subjects were standing...
متن کاملNorthwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation
BACKGROUND Current transfemoral prosthetic sockets are problematic as they restrict function, lack comfort, and cause residual limb problems. Development of a subischial socket with lower proximal trim lines is an appealing way to address this problem and may contribute to improving quality of life of persons with transfemoral amputation. OBJECTIVES The purpose of this study was to illustrate...
متن کاملTransfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: ischial containment versus brimless.
The objective of this study was to investigate the effect of brimless compared with ischial ramus containment (IRC) prosthetic sockets when using vacuum-assisted suspension (VAS) on persons with a unilateral transfemoral amputation (TFA). A randomized crossover design with a 2 d accommodation was used. People with unilateral TFA (n = 9 analyzed) were enrolled. Interventions were IRC VAS and bri...
متن کاملCoronal plane socket stability during gait in persons with transfemoral amputation: Pilot study.
Little research describes which transfemoral socket design features are important for coronal plane stability, socket comfort, and gait. Our study objectives were to (1) relate socket comfort during gait to a rank order of changes in ischial containment (IC) and tissue loading and (2) compare socket comfort during gait when tissue loading and IC were systematically manipulated. Six randomly ass...
متن کاملPiezoelectric Bimorphs' Characteristics as In-Socket Sensors for Transfemoral Amputees
Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gait & posture
دوره 34 2 شماره
صفحات -
تاریخ انتشار 2011