Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts.

نویسندگان

  • Jan Christian Brønd
  • Daniel Arvidsson
چکیده

ActiGraph acceleration data are processed through several steps (including band-pass filtering to attenuate unwanted signal frequencies) to generate the activity counts commonly used in physical activity research. We performed three experiments to investigate the effect of sampling frequency on the generation of activity counts. Ideal acceleration signals were produced in the MATLAB software. Thereafter, ActiGraph GT3X+ monitors were spun in a mechanical setup. Finally, 20 subjects performed walking and running wearing GT3X+ monitors. Acceleration data from all experiments were collected with different sampling frequencies, and activity counts were generated with the ActiLife software. With the default 30-Hz (or 60-Hz, 90-Hz) sampling frequency, the generation of activity counts was performed as intended with 50% attenuation of acceleration signals with a frequency of 2.5 Hz by the signal frequency band-pass filter. Frequencies above 5 Hz were eliminated totally. However, with other sampling frequencies, acceleration signals above 5 Hz escaped the band-pass filter to a varied degree and contributed to additional activity counts. Similar results were found for the spinning of the GT3X+ monitors, although the amount of activity counts generated was less, indicating that raw data stored in the GT3X+ monitor is processed. Between 600 and 1,600 more counts per minute were generated with the sampling frequencies 40 and 100 Hz compared with 30 Hz during running. Sampling frequency affects the processing of ActiGraph acceleration data to activity counts. Researchers need to be aware of this error when selecting sampling frequencies other than the default 30 Hz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sampling frequency affects the processing of ActiGraph 1 raw acceleration data to activity counts

([email protected])1,2* 4 1Center for Research in Childhood Health, Department of Sports Science and Clinical 5 Biomechanics, University of Southern Denmark, Denmark 6 2Unit for Clinical Physiology and Nuclear Medicine, Department of Translational 7 Medicine, Lund University, Sweden 8 9 *Daniel Arvidsson (corresponding author) 10 Center for Research in Childhood Health, Department of S...

متن کامل

Exploring the ActiLife(®) filtration algorithm: converting raw acceleration data to counts.

Though portable accelerometers are ubiquitous in physiology and public health studies, their accuracy as objective measures of physical activity is still being examined. This paper enumerates and analyzes the various biases of the widely used ActiLife(®) software in reporting activity counts from ActiGraph(®) accelerometers. In particular, we focus on the two-stage proprietary filtration algori...

متن کامل

Biomechanical examination of the 'plateau phenomenon' in ActiGraph vertical activity counts.

This paper determines if the leveling off ('plateau/inverted-U' phenomenon) of vertical ActiGraph activity counts during running at higher speeds is attributable to the monitor's signal filtering and acceleration detection characteristics. Ten endurance-trained male participants (mean (SD) age = 28.2 (4.7) years) walked at 3, 5 and 7 km h(-1), and ran at 8, 10, 12, 14, 16, 18 and 20 km h(-1) on...

متن کامل

Comparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors

PURPOSE To compare raw acceleration output of the ActiGraph™ GT3X+ and GENEA activity monitors. METHODS A GT3X+ and GENEA were oscillated in an orbital shaker at frequencies ranging from 0.7 to 4.0 Hz (ten 2-min trials/frequency) on a fixed radius of 5.08 cm. Additionally, 10 participants (age = 23.8 ± 5.4 years) wore the GT3X+ and GENEA on the dominant wrist and performed treadmill walking (...

متن کامل

Accelerometer counts and raw acceleration output in relation to mechanical loading.

The purpose of this study was to assess the relationship of accelerometer output, in counts (ActiGraph GT1M) and as raw accelerations (ActiGraph GT3X+ and GENEA), with ground reaction force (GRF) in adults. Ten participants (age: 29.4 ± 8.2 yr, mass: 74.3 ± 9.8 kg, height: 1.76 ± 0.09 m) performed eight trials each of: slow walking, brisk walking, slow running, faster running and box drops. GRF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 120 3  شماره 

صفحات  -

تاریخ انتشار 2016