Rationally Manipulating Aptamer Binding Affinities in a Stem-Loop Molecular Beacon
نویسندگان
چکیده
Single-stranded DNA sequences that are highly specific for a target ligand are called aptamers. While the incorporation of aptamer sequences into stem-loop molecular beacons has become an essential tool in optical biosensors, the design principles that determine the magnitude of binding affinity and its relationship to placement of the aptamer sequence in the stem-loop architecture are not well defined. By controlled placement of the aptamer along the loop region of the molecular beacon, it is observed that the binding affinity can be tuned over 4 orders of magnitude (1.3 nM - 203 μM) for the Huizenga and Szostak ATP DNA aptamer sequence. It is observed that the Kd is enhanced for the fully exposed sequence, with reduced binding affinity when the aptamer is part of the stem region of the beacon. Analysis of the ΔG values indicate a clear correlation between the aptamer hybridized length in the stem and its observed Kd. The use of a nanometal surface energy transfer probe method for monitoring ATP binding to the aptamer sequence allows the observation of negative cooperativity between the two ATP binding events. Maintenance of the high binding affinity of this ATP aptamer and the observation of two separate Kd's for ATP binding indicate NSET as an effective, nonmanipulative, optical method for tracking biomolecular changes.
منابع مشابه
Aptamer beacons for the direct detection of proteins.
We have designed a new class of molecules, which we term aptamer beacons, for detecting a wide range of ligands. Similar to molecular beacons, aptamer beacons can adopt two or more conformations, one of which allows ligand binding. A fluorescence-quenching pair is used to report changes in conformation induced by ligand binding. An anti-thrombin aptamer was engineered into an aptamer beacon by ...
متن کاملPrincipal factors that determine the extension of detection range in molecular beacon aptamer/conjugated polyelectrolyte bioassays.
A strategy to extend the detection range of weakly-binding targets is reported that takes advantage of fluorescence resonance energy transfer (FRET)-based bioassays based on molecular beacon aptamers (MBAs) and cationic conjugated polyelectrolytes (CPEs). In comparison to other aptamer-target pairs, the aptamer-based adenosine triphosphate (ATP) detection assays are limited by the relatively we...
متن کاملSelective and sensitive turn-on detection of adenosine triphosphate and thrombin based on bifunctional fluorescent oligonucleotide probe.
A bifunctional fluorescent oligonucleotide probe for small molecules and protein detection has been developed based on turn on fluorescence response via the target induced structure-switching of molecular beacon. The two loops of this molecular beacon are designed in such a manner that they consist of thrombin (Tmb) aptamer sequence and adenosine triphosphate (ATP) aptamer sequence, respectivel...
متن کاملSalt-mediated two-site ligand binding by the cocaine-binding aptamer
Multisite ligand binding by proteins is commonly utilized in the regulation of biological systems and exploited in a range of biochemical technologies. Aptamers, although widely utilized in many rationally designed biochemical systems, are rarely capable of multisite ligand binding. The cocaine-binding aptamer is often used for studying and developing sensor and aptamer-based technologies. Here...
متن کاملFluorescence turn-on detection of a protein through the displaced single-stranded DNA binding protein binding to a molecular beacon.
A new approach has been developed for the highly sensitive and selective sensing of a protein. Lysozyme binding to its aptamer prevents SSB protein binding, and the subsequent binding of the free SSB protein to a molecular beacon results in a turn-on fluorescence signal, which can be used for lysozyme quantification.
متن کامل