Normative values for isometric muscle force measurements obtained with hand-held dynamometers.

نویسندگان

  • A W Andrews
  • M W Thomas
  • R W Bohannon
چکیده

BACKGROUND AND PURPOSE The extent of a patient's impairment can be established by comparing measurements of that patient's performance with normative values obtained from apparently unimpaired individuals. Only a few studies have described normative values for muscle strength measured by hand-held dynamometry. The purpose of this study of older adults, therefore, was to obtain normative values of maximum voluntary isometric force using hand-held dynamometers. SUBJECTS One hundred fifty-six asymptomatic adults (77 men, 70 women) participated in this study. The subjects' mean age was 64.4 years (SD=8.3, range=50-79). The male subjects' mean age was 64.5 years (SD=8.4, range=50-79), and the female subjects' mean age was 64.3 years (SD=8.2, range=50-79). METHODS Gender, age, dominant side, height, weight, and activity level were recorded. Eight upper-extremity movements (shoulder flexion, extension, abduction, and medial and lateral rotation; elbow flexion and extension; and wrist extension) and five lower-extremity movements (hip flexion and abduction, knee flexion and extension, and ankle dorsiflexion) were resisted by one of three experienced testers using a strain-gauge hand-held dynamometer. RESULTS Gender, age, and weight were identified as independent predictors of force for all muscle actions on both the dominant and nondominant sides. These variables were used, therefore, to create regression equations and normative values for the force of each muscle action. CONCLUSION AND DISCUSSION The reference values provided may allow clinicians who follow the described testing protocol to estimate the severity of force-generating impairments in patients aged 50 to 79 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference values for isometric muscle force among workers for the Netherlands: a comparison of reference values

BACKGROUND Muscle force is important for daily life and sports and can be measured with a handheld dynamometer. Reference values are employed to quantify a subject's muscle force. It is not unambiguous whether reference values can be generalized to other populations. Objectives in this study were; first to confirm the reliability of the utilization of hand-held dynamometers for isometric streng...

متن کامل

Reliability of isometric knee extension muscle strength measurements made by a hand-held dynamometer and a belt: a comparison of two types of device

[Purpose] The purpose of the present study was to compare the reliability of 2 hand-held dynamometers (HHD-1, 2) with different designs, by performing isometric knee muscle extension measurements two times each. [Subjects] The subjects were 40 young healthy adults. [Methods] The reliability of the measurements was examined using Bland-Altman analysis. [Results] Bland-Altman analysis found a fix...

متن کامل

Validity and Reliability of a Hand-Held Dynamometer for Dynamic Muscle Strength Assessment

To overcome the limitations of the MMT, isometric hand-held dynamometers (HHD) have been developed to aid therapists in clinics (Andrews (1991)). HHDs are generally small and portable, and measure strength objectively in kilograms, pounds or newtons. The clinician holds the HHD between his or her force-applying hand and the patient’s limb segment. The clinician stabilises the limb segment while...

متن کامل

Musculoskeletal Assessment in Soccer: A Review

Muscular strength is generally measured using either of the following methods, one repetition maximum (1RM) of a weight-lifting exercise, a resisted maximal effort and portable or laboratory-based dynamometry. The 1RM method refers to measurements of maximum strength using a strength training device such as a barbell or stationary weight-lifting machine. Dynamometry can be divided into two sepa...

متن کامل

Relationship of knee extension force to independence in sit-to-stand performance in patients receiving acute rehabilitation.

BACKGROUND AND PURPOSE The ability to rise from a chair is important for independence in everyday life. This study was conducted to determine to what extent knee extension force (KEF) could explain independence in sit-to-stand (STS) performance from a standard chair. SUBJECTS AND METHODS This was a descriptive and correlational study of patients receiving acute rehabilitation (N=107). Measure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical therapy

دوره 76 3  شماره 

صفحات  -

تاریخ انتشار 1996