A challenging lead endocarditis.

نویسندگان

  • C Mihl
  • Z Geyik
  • E C Cheriex
  • J M van Opstal
چکیده

Pacemaker/implantable cardioverter-defibrillator (ICD) lead endocarditis remains a challenging diagnosis in cardiology. Several parameters can be involved in the clinical path leading to the definite diagnosis. Clinical appearance and physical findings, together with transoesophageal echocardiography and serum levels of inflammatory parameters, are necessary in the workup towards the diagnosis. It is highly unlikely that ICD-lead vegetation is accompanied by positive blood cultures solely. We describe a case of ICD-infected endocarditis with positive blood cultures for Staphylococcus epidermidis without any physical findings or raised inflammatory parameters in serum plasma levels. In this case, three-dimensional echocardiography demonstrated an added value to two-dimensional echocardiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Contribution of PET Imaging to the Diagnosis of Septic Embolism in Patients With Pacing Lead Endocarditis.

OBJECTIVES The aim of this study was to investigate the role of 18-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) scanning in identifying septic embolism in patients with lead endocarditis. BACKGROUND Lead endocarditis may be associated with septic embolism, in which case the administration mode, type, and duration of antibiotic therapy must be adapted. H...

متن کامل

Methicillin-resistant Staphylococcus aureus infective endocarditis

Methicillin was introduced in 1959 to treat penicillin-resistant S. aureus infection, however Methicillin-resistant S. aureus (MRSA) was reported 2 years later (1). The most common organism identified in acute infective endocarditis (AIE) is still S. aureus associated with increased hospital mortality, morbidity and hospitalization. In Germany the proportion of MRSA among S. aureus microbiologi...

متن کامل

Janeway lesions: a valuable clinical sign in patients with infective endocarditis

E mbolic events are known clinical stigmata of infective endocarditis occurring in 20 to 50% of cases and are often associated with protracted bacteremia. Janeway lesions are an example of this embolic phenomenon and can be a silent clinical sign (1). In cases where patients are incapacitated to a point where history acquisition becomes challenging, identification of Janeway lesions can be an i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2010