Accuracy of C-arm measurements in assessment of paediatric femoral fracture shortening

نویسندگان

  • A. Boduch
  • M. Hennrikus
  • T. Adebayo
  • J. Brian
  • W. Hennrikus
چکیده

Purpose Spica casting of femoral shaft fractures is standard practice for young children. In 1983, Dr. Rang published an illustration demonstrating that radiographs can be misleading when measuring femoral fracture shortening. Today, fluoroscopy is used to determine shortening after closed reduction and spica casting. This paper aims to determine the accuracy of fluoroscopy when measuring 25 mm of shortening in a femur fracture sawbone model. Methods Magnification, elevation and angulation were evaluated using a femur fracture sawbone model with a fixed overlap of 25 mm. Two C-arm machines used in clinical practice were studied: the OEC 9900 Elite GE C-arm and the Fluoroscan InSight mini C-arm. Results The OEC 9900 Elite GE C-arm demonstrated a 1.75 × magnification. The Fluoroscan InSight mini C-arm demonstrated a 2.5 × magnification. An 11% and a 17% magnification with elevation of the femur to 8 cm occurred using the OEC 9900 Elite GE and the Fluoroscan InSight mini C-arm respectively. Changing the tube angulation from 0° to 60° resulted in a 36% and 16% change in measured femur fracture shortening on the OEC C-arm and Fluoroscan mini C-arm respectively. Conclusion C-arm images are inaccurate. When measuring 25 mm of shortening of a paediatric femur fracture, each machine has a unique amount of magnification that should be determined and accounted for in clinical practice. Elevation of the femur above the C-arm receiver and angulation of the femur further increase the inaccuracies when measuring 25 mm of fracture shortening. Images perpendicular to the fracture are most accurate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shortening of the Femoral Neck Following Peritrochanteric Fracture

Proximal femoral neck and peritrochanteric fractures are a devastating musculoskeletal injury resulting in markedly increased patient morbidity and mortality. As the annual incidence of fracture continues to increase, there is a recognized need to improve clinical outcomes following fixation, especially in peritrochanteric fractures. While many factors are associated with adverse patient outcom...

متن کامل

Elastic Stable Intramedullary Nailing of Femoral Shaft Fracture-Experience in 48 Children

Background: Femoral shaft fractures are an incapacitating pediatric injury accounting for 1.6% of all pediatric bonyinjuries. Management of these fractures is largely directed by age, fracture pattern, associated injuries, built of the childand socioeconomic status of the family. We retrospectively evaluated the use of elastic stable intramedullary nail (ESIN)in surgical management of femoral s...

متن کامل

A simple tip to improve the accuracy of crossed K-wire placement in the management of displaced paediatric supracondylar fractures of the humerus

BACKGROUND In 1991 Lindaman et al described a fluoroscopic technique to determine the incision site for percutaneous fixation of a slipped capital femoral epiphysis.1 Using similar principles, we describe a simple technique to improve the accuracy of crossed K-wire placement in displaced paediatric supracondylar fractures of the humerus. Although not original, our technique is very useful and w...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

Does the PFNA™ nail limit impaction in unstable intertrochanteric femoral fracture? A 115 case-control series.

INTRODUCTION Femoral neck shortening after dynamic fixation of extra-capsular fracture may impair functional results, but is rarely assessed. The present study measured impaction in stable and unstable fractures (on the Ender classification) treated by PFNA™ nail. The objectives were: 1) to validate the Ender classification to assess fracture stability; 2) to determine whether neck shortening a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017