Breath ethanol and acetone as indicators of serum glucose levels: an initial report.

نویسندگان

  • Pietro R Galassetti
  • Brian Novak
  • Dan Nemet
  • Christie Rose-Gottron
  • Dan M Cooper
  • Simone Meinardi
  • Robert Newcomb
  • Frank Zaldivar
  • Donald R Blake
چکیده

BACKGROUND Many volatile organic compounds are present in exhaled breath and may represent by-products of endogenous biological processes. Ethanol is produced via alcoholic fermentation of glucose by gut bacteria and yeast, while acetone derives from oxidations of free fatty acids, influenced by glucose metabolism. We hypothesized that the integrated analysis of breath ethanol and acetone would provide a good approximation of the blood glucose profile during a glucose load. METHODS We collected simultaneous exhaled breath gas, ambient air, and serum glucose and insulin samples from 10 healthy volunteers at baseline and during an oral glucose tolerance test (OGTT) (ingestion of 75 g of glucose followed by 120 min of sampling). Gas samples were analyzed by gas chromatography/mass spectrometry. RESULTS Mean glucose values displayed a typical OGTT pattern (rapid increase, peak values at 30-60 min, and gradual return to near baseline by 120 min). Breath ethanol displayed a similar pattern early in the test, with peak values at 30 min; this was followed by a fast return to basal levels by 60 min. Breath acetone decreased progressively below basal levels, with lowest readings obtained at 120 min. A multiple regression analysis of glucose, ethanol, and acetone was used to estimate glucose profiles that correlated with measured glucose values with an average individual correlation coefficient of 0.70, and not lower than 0.41 in any subject. CONCLUSION The integrated analysis of multiple exhaled gases may serve as a marker of blood glucose levels. Further studies are needed to assess the usefulness of this method in different populations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micropreconcentrator in LTCC Technology with Mass Spectrometry for the Detection of Acetone in Healthy and Type-1 Diabetes Mellitus Patient Breath

Breath analysis has long been recognized as a potentially attractive method for the diagnosis of several diseases. The main advantage over other diagnostic methods such as blood or urine analysis is that breath analysis is fully non-invasive, comfortable for patients and breath samples can be easily obtained. One possible future application of breath analysis may be the diagnosing and monitorin...

متن کامل

Glucose prediction by analysis of exhaled metabolites – a systematic review

BACKGROUND In critically ill patients, glucose control with insulin mandates time- and blood-consuming glucose monitoring. Blood glucose level fluctuations are accompanied by metabolomic changes that alter the composition of volatile organic compounds (VOC), which are detectable in exhaled breath. This review systematically summarizes the available data on the ability of changes in VOC composit...

متن کامل

Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps Running head: Breath acetone in type 1 diabetes

Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry (SIFT-MS) to monitor the breath of 8 patients with type...

متن کامل

Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps.

Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry to monitor the breath of eight patients with type 1 dia...

متن کامل

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes technology & therapeutics

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 2005