Denaturing high-performance liquid chromatography (DHPLC)-based prenatal diagnosis for tuberous sclerosis.

نویسندگان

  • P Bénit
  • J P Bonnefont
  • A Kara Mostefa
  • C Francannet
  • A Munnich
  • P F Ray
چکیده

Tuberous sclerosis (TSC) is a frequent autosomal-dominant condition (affecting 1 in 6000 individuals) caused by various mutations in either the hamartin (TSC1) or the tuberin gene (TSC2). This allelic and non-allelic heterogeneity makes genetic counseling and prenatal diagnosis difficult, especially as a significant proportion of TSC cases are due to de novo mutations. For this reason the identification of the disease causing mutation is mandatory for accurate counseling, yet current mutation detection methods such as single-strand conformation polymorphism (SSCP) or denaturing gradient gel electrophoresis (DGGE) are labor intensive with limited detection efficiency. Denaturing high-performance liquid chromatography (DHPLC) is a high-throughput, semi-automated mutation detection system with a reported mutation detection rate close to 100% for PCR fragments of up to 800 bp. We used a recently described DHPLC assay allowing the efficient detection of mutations in TSC1 to analyze the DNA extracted from a chorion villus sample in order to perform a prenatal diagnosis for TSC. The fetus was found not to have inherited the deleterious mutation and the DHPLC diagnosis was confirmed by haplotype analysis. This represents the first DHPLC-based prenatal diagnosis of a genetic disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of the Effectiveness of a Modified Conformation Sensitive Gel Electrophoresis with Denaturing High Performance Liquid Chromatography

Background: Several methods have been developed for detection of sequence variation in genes and each has its advantages and disadvantages. A disadvantage of them is that the simpler, cost-effective methods are commonly perceived as being less sensitive in their detection of sequence variation, whereas those with proven sensitivity have a requirement for complex or expensive laboratory equipmen...

متن کامل

Detection of CYP2C18 m1, and m2 Alleles within an Iranian Population (Mazandaran) Using Denaturing High-Performance Liquid Chromatography (DHPLC)

Background: Genetic polymorphisms of cytochrome p450 in humans are the main cause of differences in the metabolism. The allele and genotype frequencies of CYP2C19 and CYP2C9 have been studied in some Iranian populations. The aim of present study was to examine the frequencies of CYP2C18m1, and CYP2C18m2, alleles in the Mazandarani ethnic group among Iranian Population. Materials and Methods: I...

متن کامل

Evaluation of denaturing high performance liquid chromatography for the mutational analysis of the MEN1 gene.

The identification of mutations in the MEN1 gene causing MEN1 has represented a challenge since the cloning of the gene in 1997 because of the lack of mutation hot-spots in the gene and the lack of phenotype-genotype correlations. The use of denaturing high performance liquid chromatography (DHPLC), a high throughput, reliable and automated heteroduplex-based technique, is the ideal for mutatio...

متن کامل

Comparison of high-resolution melting analysis to denaturing high performance liquid chromatography in the detection of point mutations in MEFV, F5, and F2 genes.

BACKGROUND/AIM Sensitive and cost-effective detection of point mutations is important in genetics research. Denaturing high-performance liquid chromatography (DHPLC) is known to be one of the most sensitive techniques for point mutation detection. A more recent technique, high-resolution melting (HRM), is based on the melting behavior of PCR products. In this study, the efficiency and sensitivi...

متن کامل

DNA Sequence Fragment Containing C to A Mutation as a Convenient Mutation Standard for DHPLC Analysis

Objective(s):  Denaturing high performance liquid chromatography (DHPLC) is a high throughput approach for screening DNA sequence variations. To assess oven calibration, cartridge performance, buffer composition and stability, the WAVE Low and High Range Mutation Standards are employed to ensure reproducibility and accuracy of the chromatographic analysis. The purpose of this study was to provi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prenatal diagnosis

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2001