Measurement of cardiac output during exercise by open-circuit acetylene uptake.
نویسندگان
چکیده
Noninvasive measurement of cardiac output (QT) is problematic during heavy exercise. We report a new approach that avoids unpleasant rebreathing and resultant changes in alveolar PO(2) or PCO(2) by measuring short-term acetylene (C(2)H(2)) uptake by an open-circuit technique, with application of mass balance for the calculation of QT. The method assumes that alveolar and arterial C(2)H(2) pressures are the same, and we account for C(2)H(2) recirculation by extrapolating end-tidal C(2)H(2) back to breath 1 of the maneuver. We correct for incomplete gas mixing by using He in the inspired mixture. The maneuver involves switching the subject to air containing trace amounts of C(2)H(2) and He; ventilation and pressures of He, C(2)H(2), and CO(2) are measured continuously (the latter by mass spectrometer) for 20-25 breaths. Data from three subjects for whom multiple Fick O(2) measurements of QT were available showed that measurement of QT by the Fick method and by the C(2)H(2) technique was statistically similar from rest to 90% of maximal O(2) consumption (VO(2 max)). Data from 12 active women and 12 elite male athletes at rest and 90% of VO(2 max) fell on a single linear relationship, with O(2) consumption (VO(2)) predicting QT values of 9.13, 15.9, 22.6, and 29.4 l/min at VO(2) of 1, 2, 3, and 4 l/min. Mixed venous PO(2) predicted from C(2)H(2)-determined QT, measured VO(2), and arterial O(2) concentration was approximately 20-25 Torr at 90% of VO(2 max) during air breathing and 10-15 Torr during 13% O(2) breathing. This modification of previous gas uptake methods, to avoid rebreathing, produces reasonable data from rest to heavy exercise in normal subjects.
منابع مشابه
Cardiac output during exercise by the open circuit acetylene washin method: comparison with direct Fick.
An open-circuit (OpCirc) acetylene uptake cardiac output (QT) method was modified for use during exercise. Two computational techniques were used. OpCirc1 was based on the integrated uptake vs. end-tidal change in acetylene, and OpCirc2 was based on an iterative finite difference modeling method. Six subjects [28-44 yr, peak oxygen consumption (VO(2)) = 120% predicted] performed cycle ergometry...
متن کاملDifferences of cardiac output measurements by open-circuit acetylene uptake in pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension: a cohort study
BACKGROUND As differences in gas exchange between pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) have been demonstrated, we asked if cardiac output measurements determined by acetylene (C2H2) uptake significantly differed in these diseases when compared to the thermodilution technique. METHOD Single-breath open-circuit C2H2 uptake, thermodiluti...
متن کاملValidation of a new spectrometer for noninvasive measurement of cardiac output
Acetylene is a blood-soluble gas and for many years its uptake rate during rebreathing tests has been used to calculate the flow rate of blood through the lungs ~normally equal to cardiac output! as well as the volume of lung tissue. A new, portable, noninvasive instrument for cardiac output determination using the acetylene uptake method is described. The analyzer relies on nondispersive IR ab...
متن کاملCorrection of cardiac output obtained by Modelflow from finger pulse pressure profiles with a respiratory method in humans.
The beat-by-beat non-invasive assessment of cardiac output (Q litre x min(-1)) based on the arterial pulse pressure analysis called Modelflow can be a very useful tool for quantifying the cardiovascular adjustments occurring in exercising humans. Q was measured in nine young subjects at rest and during steady-state cycling exercise performed at 50, 100, 150 and 200 W by using Modelflow applied ...
متن کاملSystemic and vastus lateralis muscle blood flow and O2 extraction during ramp incremental cycle exercise.
During ramp incremental cycling exercise increases in pulmonary O2 uptake (Vo2p) are matched by a linear increase in systemic cardiac output (Q). However, it has been suggested that blood flow in the active muscle microvasculature does not display similar linearity in blood flow relative to metabolic demand. This study simultaneously examined both systemic and regional (microvascular) blood flo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 87 4 شماره
صفحات -
تاریخ انتشار 1999