FLUORIDE RELEASE OF SIX RESTORATIVE MATERIALS IN WATER AND pH-CYCLING SOLUTIONS

نویسندگان

  • Rosa Maria Viana de Bragança Garcez
  • Marília Afonso Rabelo Buzalaf
  • Paulo Amarante de Araújo
چکیده

The fluoride release of restorative materials in deionized water has been the subject of many studies, but the behavior of these materials under conditions of acid challenge that simulates the oral cavity, needs to be further explored. Therefore, the aim of this study was to evaluate the fluoride release of restorative materials in two storage protocols: deionized water and pH-cycling system (demineralizing solution-pH 4.3 and remineralizing solution-pH 7.0) for 15 days. Eight disks of each material (Vitremer-positive control, Dyract AP, Ariston pHc, Definite, TetricCeram and Z100-negative control) were prepared (11.0 mm x 1.5 mm) and suspended individually in 4.0 mL of each solution, which were daily changed. Daily fluoride release was analyzed with an ion specific electrode (Orion 9609) by the direct method or after HMDS-facilitated diffusion, following 1, 7 and 15 days. The values obtained were converted into microgF/mm(2) and the data analyzed by ANOVA and Tukey's test (p< 0.05). The results showed that all materials released more fluoride in the pH-cycling system, except for Ariston pHc which maintained a constant release during the experiment. The highest fluoride release was presented by the positive control, Vitremer in pH-cycling and by Ariston pHc, in deionized water. The negative control Z100 and the resins Definite and TetricCeram did not present statistically significant differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microhardness and fluoride release of restorative materials in different storage media.

This study evaluated the surface microhardness and fluoride release of 5 restorative materials - Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil - in two storage media: distilled/deionized water and a pH-cycling (pH 4.6). Twelve specimens of each material, were fabricated and the initial surface microhardness (ISM) was determined in a Shimadzu HMV-2000 microhardness tester (static l...

متن کامل

Estimation of Fluoride Release from Various Dental Materials in Different Media—An In Vitro Study

PURPOSE This study was performed to study the pattern of fluoride release from glass ionomer cement, a resin modified glass ionomer cement, a compomer and a composite resin when stored in different storage media. METHODS A total of 60 samples (Tablets of diameter 8.6 ± 0.1 mm and thickness 1.65 ± 0.1 mm) were prepared (15 samples for each material) pertaining to 4 different materials used. Fi...

متن کامل

Effect of acetic NaF solutions on fluoride-containing dental restorative materials.

The aim of this study was to evaluate the effect of acetic NaF solutions on fluoride-containing restorative materials. As the pH value of solution decreased, the degree of microhardness change in restorative materials increased- regardless of product. Dyract AP (DA) and F2000 (F2) (polyacid-modified resin composites) showed the greatest decrease in microhardness after immersion for three days. ...

متن کامل

Cariostatic effect of fluoride-containing restorative materials associated with fluoride gels on root dentin

UNLABELLED Secondary caries is still the main cause of restoration replacement, especially on the root surface. OBJECTIVE This in vitro study evaluated the cariostatic effects of fluoride-containing restorative materials associated with fluoride gels, on root dentin. MATERIALS AND METHODS A randomized complete block design was used to test the effects of the restorative systems, fluoride re...

متن کامل

In vitro evaluation of topical fluoride pH and their effect on surface hardness of composite resin-based restorative materials.

AIM The aim of the study was to correlate the pH and fluoride ion uptake with surface hardness of composite resin based restorative materials after topical fluoride application. METHODOLOGY Forty disks of each of test materials Composite (Filtek Z350XT, 3M ESPE, St Paul, MN, USA), Resin modified glass ionomer (Vitremer) and Compomer (Dyract AP) were made and ten disks of each material were pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2007